Why Cannot I Receive a Job Failure Alarm Notification After SMN Is Configured?
Updated on 2023-06-21 GMT+08:00
Why Cannot I Receive a Job Failure Alarm Notification After SMN Is Configured?
What can I do if the SMN notification for job exception/failure is configured but the alarm notification for job exception/failure is not received?
Figure 1 Notification management
![](https://support.huaweicloud.com/intl/en-us/dataartsstudio_faq/en-us_image_0000001487091470.png)
To solve the problem, perform the following steps:
- Check whether the failed job is being scheduled. No notification is sent for jobs in the test running state. SMN notifications are sent only for jobs in the scheduling state.
- On the Data Development page, choose to check whether the notification function is enabled.
- Log in to the SMN console and check whether the SMN topic has been subscribed to.
- Check whether the subscription endpoint of the SMN topic has its own name and whether the subscription is confirmed.
- Check whether the SMN channel is normal. You can send messages to your topic on the SMN console to check whether you can receive notifications from SMN.