Help Center/ ModelArts/ Troubleshooting/ Resource Pool/ Faulty Nodes in a Resource Pool
Updated on 2026-11-10 GMT+08:00

Faulty Nodes in a Resource Pool

Locating Faulty Nodes

In a dedicated resource pool, ModelArts will add a taint to a faulty Kubernetes node so that jobs will not be scheduled to the tainted node. The following table lists the faults can be detected. You can locate the fault by referring to the isolation code and detection method.

Table 1 Isolation code

Isolation Code

Category

Sub-Category

Description

Detection Method

A050101

GPU

Video RAM

GPU ECC error.

Run the nvidia-smi -a command and check whether Pending Page Blacklist is Yes or the multi-bit register file is greater than 0. For Ampere GPUs, check whether any of the following situations occurs:

  • Uncorrectable SRAM error
  • Remapping Failure records
  • Xid 95 events in dmsg

The Ampere architecture has the following levels of GPU memory errors:

  • L1: These are single-bit ECC errors that can be corrected. They do not affect the running services. To check for these errors, run the nvidia-smi -a command and look for Volatile Correctable.
  • L2: These are multi-bit ECC errors that cannot be corrected. They cause the running services to fail and require a process restart to recover. To check for these errors, run the nvidia-smi -a command and look for Volatile Uncorrectable.
  • L3: These are unsuppressed errors and may affect other services. They require a card reset or a node reboot to clear. To check for these errors, look for the Xid events that contain the number 95. (The Remapped Pending records are only for reference. You need to reset the cards when the service is idle to trigger the remapping process.)
  • L4: These are errors that require a card replacement. To check for these errors, look for the SRAM Uncorrectable field that is greater than 4 or the Remapped Failed field that is not zero.

A050102

GPU

Other

The nvidia-smi output contains ERR.

Run nvidia-smi -a and check whether the output contains ERR!. Normally, such errors are caused by hardware faults, such as the faulty power supply or fan.

A050103

GPU

Other

The execution of nvidia-smi times out or does not exist.

Check that the exit code of nvidia-smi is not 0.

A050104

GPU

Video RAM

The ECC error has occurred 64 times.

Run the nvidia-smi -a command, locate Retired Pages, and check whether the sum of Single Bit and Double Bit is greater than 64.

A050148

GPU

Other

An infoROM alarm is generated.

Run the nvidia-smi command and check whether the output contains alarm infoROM is corrupted.

A050109

GPU

Other

Other GPU errors.

Check whether other GPU errors exist. Normally, such errors are caused by faulty hardware. Contact the technical support.

A050147

IB

Link

The InfiniBand NIC is abnormal.

Run the ibstat command and check whether the NIC is not in the active state.

A050121

NPU

Other

A driver exception is detected by NPU DCMI.

Check whether the NPU driver environment is abnormal.

A050122

NPU

Other

The NPU DCMI device is abnormal.

Check whether the NPU device is abnormal and the Ascend DCMI API returns a major or critical alarm.

A050123

NPU

Link

The 1520 subhealth check is abnormal.

1520 subhealth. Fault level: pre-isolation

A050124

NPU

Other

The 1520 subhealth check is abnormal.

1520 subhealth. Fault level: isolation

A050128

NPU

Other

NPU residual process detection.

Obtain raw information from the DevicePlugin to check whether there are residual processes.

A050967

NPU

Other

NPU high-frequency faults.

Obtain information from the node annotations to determine whether high-frequency faults have occurred.

A050129

NPU

Other

Other NPU errors.

Check whether other NPU errors exist. Such errors usually should be corrected with the assistance of the technical support.

A050149

NPU

Link

hccn tool network port link flapping check.

The NPU network is unstable and intermittently disconnected. Run the hccn_tool-i ${device_id} -link_stat -g command to check whether the network has been intermittently disconnected more than five times within 4 hours.

A050951

NPU

Video RAM

The number of NPU ECC errors reaches the repair threshold.

Check whether the NPU's HBM Double Bit Isolated Pages Count value is greater than or equal to 64.

A050821

NPU

Link

The 1825 NIC is in the subhealthy state.

The 1825 NIC of the node is in the subhealthy state. You can use dpu-info-<nodename> configmap to obtain the fault details.

A050822

NPU

Link

The 1825 NIC is faulty.

The 1825 NIC of the node is faulty. You can use dpu-info-<nodename> configmap to obtain the fault details.

A050823

NPU

Link

The UB port is abnormal.

Run the hccn_tool -g -dev_info -i ${device_id} command. A UB port in the DOWN state exists.

A050146

Runtime

Other

The NTP is abnormal.

Check whether the NTPD or Chronyd service is abnormal.

A050202

Runtime

Other

The node is not ready.

Check whether the node is unavailable. An unavailable Kubernetes node may have one of the following taints:

  • node.kubernetes.io/unreachable
  • node.kubernetes.io/not-ready

A050203

Runtime

Disconnected PU

The number of normal AI cards does not match the actual capacity.

Check whether the GPU or NPU is disconnected.

A050204

Runtime

Other

NPU L1-L5 fault information.

Check the contents of metadata.annotations."os.modelarts.node/fault-info". In general, this refers to PU disconnection faults other than A050203.

A050206

Runtime

Other

The Kubelet hard disk is read-only.

Check whether the /mnt/paas/kubernetes/kubelet directory is read-only.

A050955

Runtime

Other

SFS Turbo Client+ installation failure.

Installation fails after downloading the SFS Turbo Client+ package from the OBS bucket on the SFS side. The cause is unknown and requires intervention by the O&M team.

A050956

Runtime

Other

SFS Turbo Client+ version mismatch.

Use the modInfo command to check the current NFS version on the node. If the version does not match the preconfigured environment variable value, this fault is triggered and the node is isolated.

A050801

Node management

Node O&M

Resources are reserved.

Check whether the node is marked as a standby and has a taint.

A050802

Node management

Node O&M

Unknown error.

Check whether the node is marked with an unknown taint.

A050803

Node management

Node O&M

Unknown error.

Check whether the node is marked with a critical unknown taint.

A050805

Node management

Node O&M

O&M authorization.

Submit an O&M authorization request to the user for approval.

A050806

Node management

Node O&M

Isolate standby nodes and replace retained nodes.

Isolate standby nodes and replace retained nodes.

A050807

Node management

Node O&M

A node is undergoing replacement.

This fault code is added and the node is isolated during node replacement or when a faulty node is retained.

A050810

Node management

Node O&M

Same error code occurs for multiple times.

When the same fault code occurs multiple times consecutively on the same node, ModelArts OS automatically escalates it to this fault.

A050817

Node management

Node O&M

Redeployment-associated isolation of healthy nodes.

When SliceHA is triggered, a fault instance is created for each healthy node within the slice to isolate healthy nodes that share the same slice as the faulty node.

A200001

Node management

Driver upgrade

The GPU is being upgraded.

Check whether the GPU is being upgraded on the node.

A200002

Node management

Driver upgrade

The NPU is being upgraded.

Check whether the NPU is being upgraded on the node.

A050963

Node management

Driver upgrade

The NPU driver upgrade is faulty.

Check whether the NPU driver upgrade is in the pending or abnormal state.

A200008

Node management

Node admission

The admission is being examined.

Check whether the admission is being examined on the node, including basic node configuration check and simple service verification.

A050933

Node management

Failover

The failover service on the tainted node will be migrated.

Check whether the node is marked with the taint and its failover service is migrated.

A050968

Node management

Network

NIC receive queue anomaly.

Check the node's network receive queues to determine whether packets are being received only on queue 0.

A050965

Node management

Other

Node resources are frozen.

In CloudScopeV2, check the value of the metadata.annotations[os.modelarts/billing.status] field in the ModelArts OS node's CR. Determine whether the field is empty.

A050966

Node management

Other

Abnormal weight warmup item clearance on the node.

The weight warmup pod has been deleted, but a tmpfs mount point named /tmp/ckpt-warm-up-xxx still exists on the node.

A050931

Training toolkit

Pre-check container

A GPU error is detected in the pre-check container.

Check whether a GPU error is detected in the pre-check container.

A050932

Training toolkit

Pre-check container

An InfiniBand error is detected in the pre-check container.

Check whether an InfiniBand error is detected in the pre-check container.

A050804

Hardware fault

Hardware fault

Detected through hardware alarms.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050808

Hardware fault

Hardware subhealth

Underlying hardware subhealth.

An underlying hardware fault is detected. Currently, detection is integrated through CAR diagnostics. After the customer authorizes a node restart, if the fault remains unresolved after 10 minutes, it is automatically escalated to A050809.

A050809

Hardware fault

Hardware subhealth

Underlying hardware subhealth.

After a node enters a sub-healthy state, the node is restarted. If the fault remains unresolved after 10 minutes, ModelArts OS automatically escalates it to this fault.

A050811

Hardware fault

Hardware subhealth

Cloud Eye-detected underlying hardware sub-health.

Cloud Eye detects underlying hardware faults. Currently, detection is automatically integrated through CAR.

Cloud Eye does not currently support automatic alarm recovery and cannot determine whether a fault has recovered after a restart. Therefore, automatic escalation to in-place repair and automatic fault closure are not supported for the time being.

A050812

Hardware fault

Hardware subhealth

A hardware alarm indicates that a hyperplane L1 subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050813

Hardware fault

Hardware subhealth

A hardware alarm indicates that a hyperplane L2 subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050814

Hardware fault

Hardware subhealth

A hardware alarm indicates that a hyperplane L3 subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050815

Hardware fault

Hardware subhealth

A hardware alarm indicates that a parameter plane L1 subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050816

Hardware fault

Hardware subhealth

A hardware alarm indicates that a parameter plane L2 subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050820

Hardware fault

Hardware subhealth

A hardware alarm indicates that a server subhealth fault occurs.

Detected through hardware alarms.

Authorize O&M in Event Center. For details, see Authorizing O&M on the Event Center Page.

A050899

Hardware fault

Other

Collaborative hardware maintenance.

A hardware fault is found through alarm monitoring. To fix the faulty hardware, related parts must stop working.

21000022

DPU (1825 NIC)

HCA port

The 1825 HCA port is faulty (hca_port_down). The RoCE device port status is abnormal, affecting the communication link between the NPU and DPU.

Run the cat /sys/class/infiniband/$hca/ports/1/state and cat /sys/class/infiniband/$hca/ports/1/phys_state commands to read the RoCE device port status. If the port status is abnormal, the port is faulty.

This only applies to A5.

21000023

DPU (1825 NIC)

UB link

If some lanes between the 1825 NIC and NPU are faulty (part_lane_down), the data plane bandwidth decreases but is not completely disconnected. Services are not affected, but performance is affected.

Use the Hinicadmfdx3 tool to check the link bit width of the port. Run the hinicadmdfx3 pcie_topo -i ${hca_name} -a command to check the cap and cur values. If the values are different, a lane reduction fault occurs.

This only applies to A5.

21000025

DPU (1825 NIC)

Ethernet port

The 1825 outbound port is faulty (eth_port_down). The NIC's external network port is abnormal, affecting outbound communication.

Run the cat /sys/class/infiniband/$hca/ports/1/state and cat /sys/class/infiniband/$hca/ports/1/phys_state commands to read the RoCE device port status. If the port status is abnormal, the port is faulty.

This only applies to A5.

A050208

Disk

Partitioning

Missing container disk partition.

Node disk partition anomaly: missing container disk partition will cause container startup failures.

Configuring Node Event Alarm Notifications

AOM automatically reports node fault events by default. You can set up SMS or email notifications through AOM.

The following steps are performed on AOM 2.0.

  1. Log in to the AOM console.
  2. In the navigation pane, choose Alarm Center > Alarm Rules. Then, click Create Alarm Rule in the upper right corner.
  3. Set an alarm rule (using error code A050804 as an example).

    • Rule Type: Select Event alarm rule.
    • Event Type: Select System.
    • Event Source: Select ModelArts.
    • Monitored Object: Filter monitored objects by custom attributes. The event format is code=${Error code}.

      This example uses the code=A050804 with Trigger Mode set to Immediate Trigger.

    • Alarm Mode: Select Direct alarm reporting.
    • (Optional) Alarm Notification: To get notified of alarms by email or SMS message, configure action rules for the alarm rule. If no action rule is available, you can create one.