Updated on 2024-01-25 GMT+08:00

ALM-303046659 The temperature is abnormal 140545

Description

ENTITYTRAP/1/ENTITYBRDTEMPALARM: OID [OID] Temperature rise over or fall below the warning alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])

The temperature of the board falls below the lower threshold.

Attribute

Alarm ID

Alarm Severity

Alarm Type

303046659

Critical

environmentalAlarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Indicates the index.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the name of the physical entity.

EntityThresholdType

Indicates the threshold type of the physical entity.

EntityThresholdValue

Indicates the threshold value of the physical entity.

EntityThresholdCurrent

Indicates the current value of the physical entity.

EntityTrapFaultID

Indicates the error code.

Impact on the System

Services on the board may be affected if the temperature becomes too low.

Possible Causes

The ambient temperature is too low.

Procedure

  1. Measure the ambient temperature. If the ambient temperature is too low, use air conditioners or heaters to increase the temperature.
  2. If the ambient temperature is normal, the lower threshold of the temperature may be too high. Run the temperature threshold slot slotid lower-limit lower upper-limit upper command to decrease the lower threshold of the temperature.

Related Information

None