ALM-135471444 hwOpticalUnAuthorized
Description
The optical module was not certified by Huawei. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])
The optical module is not a Huawei certified one.
Attribute
AlarmID |
Alarm OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
135471444 |
1.3.6.1.4.1.2011.5.25.219.2.4.9 |
Critical |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
EntPhysicalIndex |
Entity index. |
EntPhysicalName |
Entity Name |
EntityTrapFaultID |
Alarm cause |
Reason |
Impact on the System
If the optical module is delivered by Huawei in the early stage, the system is not affected. If not, the optical module may be abnormal, causing service interruption.
Possible Causes
An optical module that is not certified for Huawei was installed. Alarms may be generated because vendor information of Huawei early delivered optical modules is not recorded.
Procedure
1. If the optical modules are early delivered from Huawei, run the transceiver non-certified-alarm disable command to disable the alarm function for non-Huawei-certified optical modules.
2. If the optical module is not delivered by Huawei or is not a Huawei-certified optical module, replace it with a Huawei-certified optical module.
Related Information
None.