Updated on 2026-10-21 GMT+08:00

CM Server Parameters

log_dir

Parameter description: Specifies the directory where CM Server logs are stored. The value can be an absolute path, or a path relative to the CM Server data directory.

Parameter type: string.

Unit: none

Value range: valid path of a directory.

Default value: "$GAUSSLOG/cm/cm_server", indicating that the CM Server logs are generated in the CM directory in $GAUSSLOG.

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

log_file_size

Parameter description: Specifies the size of a log file. If a log file exceeds the specified size, a new one is created to record logs.

Parameter type: integer.

Unit: MB

Value range: 0 to 2047

Default value: 16

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2. For example, if this parameter is set to 16 without a unit, it indicates 16 MB. If this parameter is set to 16MB, it indicates 16 MB. The unit must be MB if required.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

log_min_messages

Parameter description: Specifies the level of messages to be written to the CM Server log. Each level covers all the levels following it. The lower the level is, the fewer messages will be written into the log.

Parameter type: enumerated type

Unit: none

Value range: debug5, debug1, log, warning, error, and fatal.

Default value: warning

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Set this parameter based on the hard disk size.

Risks and impacts of improper settings: If a low level is set, debugging information may be lost.

thread_count

Parameter description: Specifies the number of threads in the agent thread pool.

Parameter type: string.

Unit: none

Value range: This parameter consists of two parts: 'worker_thread_count and io_ratio. The meanings of the two parts are as follows:

  • worker_thread_count: specifies the number of AgentWorker threads. The value ranges from 2 to 1000.
  • io_ratio: specifies the ratio of I/O threads to worker threads. The value n indicates that one AgentIO thread corresponds to n AgentWorker threads. The value ranges from 1 to 100. At least one AgentIO thread is required.

If the value of worker_thread_count, namely the number of AgentWorker threads, is greater than the sum of the number of cluster nodes and the number of threads for processing cm_ctl requests (if the number of cluster nodes is less than 32, one thread is used by default; otherwise, four threads are used), the value that takes effect is the sum of the number of cluster nodes and the number of threads for processing cm_ctl requests.

Default value: "(1000,1)"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Retain the default value. If you want to adjust the value, make sure you understand the parameter meaning and adjust the value with caution to avoid risks caused by misoperations.

Risks and impacts of improper settings: If this parameter is incorrectly set, CM faults may not be detected and rectified in a timely manner, and the CPU load may increase.

thread_effective_time

Parameter description: Specifies the timeout interval for a round of thread running. If the timeout occurs, the thread is suspended and the process automatically exits.

Parameter type: integer.

Unit: seconds

Value range: 0 to 1200. The value 0 indicates that the thread monitoring capability is disabled.

Default value: 20

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 3.

Setting suggestion: You are advised not to change the parameter value. If you need to change the parameter value, contact Huawei technical support.

Risks and impacts of improper settings: Improper settings may cause inaccurate fault detection and delayed fault rectification.

ctl_thread_count

Parameter description: Specifies the number of threads in the ctl thread pool.

Parameter type: string.

Unit: none

Value range:

The value is a string of more than 0 characters. This parameter consists of two parts: worker_thread_count and io_ratio. The meanings of the two parts are as follows:

  • worker_thread_count: specifies the number of CtlWorker threads. The value ranges from 0 to 1000. If the value is 0, the number of CtlWorker threads is equal to the number of nodes in the cluster.

  • io_ratio: specifies the ratio of I/O threads to worker threads. The value n indicates that one CtlIO thread corresponds to n CtlWorker threads. The value ranges from 1 to 100. At least one CtlIO thread is required.

Default value: "(0,1)"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: CM performance may deteriorate.

alarm_component

Parameter description: Specifies the location of the alarm component that processes alarms.

Parameter type: string.

Unit: none

Value range: valid file path.

  • If --alarm-type in the gs_preinstall script is set to 5, no third-party component is connected and alarms are written into system_alarm logs. In this case, the value of alarm_component is /opt/huawei/snas/bin/snas_cm_cmd.
  • If --alarm-type in the gs_preinstall script is set to 1, a third-party component is connected. In this case, the value of the GUC parameter alarm_component is the absolute path of the executable program of the third-party component.

Default value: "/opt/huawei/snas/bin/snas_cm_cmd"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

alarm_report_interval

Parameter description: Specifies the interval at which an alarm is reported.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 3

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, alarms may not be reported in a timely manner. If the value is too small, the CPU load may increase.

alarm_report_max_count

Parameter description: Specifies the maximum number of times an alarm is reported.

Parameter type: integer.

Unit: none

Value range: 1 to 2592000

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, the CPU load may increase.

instance_failover_delay_timeout

Parameter description: Specifies the delay in CM Server failover after the primary CM Server breakdown is detected. It takes effect for GTM arbitration.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, database faults may not be rectified in a timely manner.

instance_heartbeat_timeout

Parameter description: Specifies the timeout interval for CM Server to detect the instance heartbeat.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2147483647

Default value: 6

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

instance_keep_heartbeat_timeout

Parameter description: The CM Agent periodically checks the instance status and reports the status to the CM Server. If the instance status cannot be detected for a long time and the accumulated time exceeds the value of this parameter, the CM Server delivers a command to the CM Agent to restart the instance.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 40

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

instance_phony_dead_restart_interval

Parameter description: Specifies the interval at which the CM Agent process restarts and kills a zombie CN, DN, or GTM instance. The interval between two consecutive kill operations cannot be less than the value of this parameter. Otherwise, the CM Agent process does not deliver commands.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

coordinator_heartbeat_timeout

Parameter description: Specifies the heartbeat timeout that triggers the automatic removal of faulty CNs. The setting of this parameter takes effect immediately, and you do not need to restart the cluster.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2592000. 0 indicates that a faulty CN will not be automatically removed.

Default value: 25

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, the CN may fail to be removed for a long time. If the value is too small, the CN may fail to be removed.

phony_dead_effective_time

Parameter description: Specifies the maximum number of times CN, DN, or GTM processes are detected as zombie. If the number of times a process is detected as zombie is greater than the specified value, the process is considered as a zombie process and will be restarted.

Parameter type: integer.

Unit: none

Value range: 1 to 2147483647

Default value: 5

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

enable_transaction_read_only

Parameter description: Specifies whether to enable the threshold detection function of the CM Server disk. After this function is enabled, CM Server automatically sets the database to read-only when the disk usage is greater than the value of datastorage_threshold_value_check.

Parameter type: Boolean

Unit: none

Value range:

  • on: The threshold detection function is enabled.
  • off: The threshold detection function is disabled.

Default value: on

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Disabling this function may cause high disk usage.

enable_disk_full_check

Parameter description: Specifies whether to enable the check for full disks. (If the disk usage exceeds the value of disk_full_threshold, instance processes on the faulty node will be stopped.)

Parameter type: Boolean

Unit: none

Value range:

  • on: The disk full check is enabled.
  • off: The disk full check is disabled.

Default value: on

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

disk_full_threshold

Parameter description: Specifies the disk usage threshold in a database. When the disk usage of the data directory exceeds the specified value, the disk is full and the database is automatically stopped. When the disk usage is less than the value specified by datastorage_threshold_value_check, the database is automatically started. The value of disk_full_threshold takes effect only when it is greater than that of datastorage_threshold_value_check.

Parameter type: integer.

Unit: %

Value range: 1 to 99

Default value: 98

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, other processes may be unavailable.

datastorage_threshold_check_interval

Parameter description: Specifies the interval for checking the disk usage. The system checks the disk usage at the interval specified by the user.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2592000

Default value: 10

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, CM fault detection and recovery cannot be performed in a timely manner. If the value is too small, the CPU load increases.

datastorage_threshold_value_check

Parameter description: Specifies the usage threshold of a read-only disk in a database. When the disk usage of the data directory exceeds the specified value, the database is automatically set to read-only mode. In the read-only mode, log replay cannot be restricted and the disk usage increases. Therefore, you need to pay attention to the cluster disk capacity and handle read-only alarms in a timely manner to prevent the disk space from being used up; otherwise, the database cannot be restored quickly.

Parameter type: integer.

Unit: %

Value range: 1 to 99

Default value: 85

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value. You can adjust this parameter based on the disk space. When adjusting this parameter, you are advised to adjust the max_size_for_xlog_retention parameter of the DN at the same time to prevent the cluster read-only threshold from being triggered by backup operations.

This parameter is default to 85% considering the following factors:
  • GaussDB is usually used to carry core services featuring large storage capacity and high concurrency requirements. Therefore, reserving 15% of the space ensures that there is enough space to allow for data increase during the period before storage scale-up when the disk space is insufficient.
  • Disk space is reserved for O&M operations after the database enters the read-only mode, such as log processing, space recycling, and backup, to ensure sufficient space for O&M operations when a problem occurs.
  • Most customers prefer the default setting of 85%.

Risks and impacts of improper settings: If the value is too large, the disk space usage is too high and the restoration cannot be achieved quickly.

datastorage_threshold_recover

Parameter description: Specifies the buffer threshold for canceling the database read-only mode. If the disk usage of the data directory exceeds the value of datastorage_threshold_value_check, the data directory is set to read-only. The read-only mode is disabled only when the disk usage is less than the value of datastorage_threshold_value_check minus datastorage_threshold_recover. For a removed CN, to prevent repeated removal and addition, the CN can be added only when the disk usage is less than the value of datastorage_threshold_value_check minus datastorage_threshold_recover. If the disk usage exceeds the value, the CN cannot be added back. After the primary database becomes read-only, a switchover can be performed only when the disk usage of the standby database is less than the value of datastorage_threshold_value_check minus datastorage_threshold_recover.

Parameter type: integer.

Unit: %

Value range: 0 to 99

Default value: 5

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

max_datastorage_threshold_check

Parameter description: Specifies the maximum interval for checking the disk usage. After you modify the read-only mode parameter, the system automatically checks whether the disk usage reaches the threshold at the specified interval.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2592000

Default value: 43200

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, CM fault detection and recovery cannot be performed in a timely manner.

enable_az_auto_switchover

Parameter description: Specifies whether to enable the automatic copy reduction function.

Parameter type: integer.

Unit: none

Value range: 0 to 1

  • 0: disabled.
  • 1: enabled.

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If this function is disabled, the CM cannot restore the cluster by reducing copies when a majority of nodes are faulty.

enable_az_conn_check

Parameter description: Specifies whether to enable AZ network arbitration. The CM Server will shut down the isolated AZ.

Parameter type: integer.

Unit: none

Value range: 0 to 1

  • 0: disabled.
  • 1: enabled. After this function is enabled, the CM Server performs AZ network arbitration.

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cm_auth_method

Parameter description: Specifies the port authentication mode of the CM module.

Parameter type: enumerated type

Unit: none

Value range:

  • trust: Port authentication is not configured.
  • gss: Kerberos port authentication is used.

Default value: trust

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: You can change the value to "gss" only after the Kerberos server and client are successfully installed. Otherwise, the CM cannot communicate properly, affecting the cluster status.

cm_krb_server_keyfile

Parameter description: Specifies the location of the key file on the Kerberos server. The value must be an absolute path. The file is usually stored in the ${GAUSSHOME}/kerberos directory and ends with keytab. The file name is the same as the name of the user who runs the cluster.

Parameter type: string.

Unit: none

Value range: absolute path of the key file of the Kerberos server.

Default value: ${GAUSSHOME}/kerberos/{UserName}.keytab. The default value cannot take effect and is used only as a prompt.

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: This parameter is paired with the preceding parameter cm_auth_method. When cm_auth_method is set to "gss", this parameter must be set to a correct path. Otherwise, the cluster status will be affected.

cm_hadr_process_type

Parameter description: Specifies the DR process ID.

Parameter type: enumerated type

Unit: none

Value range:

  • none: There is no process.
  • failover: A standby cluster for DR is promoted to primary.
  • switchover_promote: A standby cluster for DR is promoted to primary during the cluster switchover.
  • switchover_demote: A primary cluster is demoted to a standby cluster for DR during the cluster switchover.

Default value: none

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cma_fault_kill_instance_timeout

Parameter description: Specifies timeout interval for waiting for a DN to be reported after the internal status of the primary CM Server is set to unknown. The CM Server runs the pssh command to remotely kill the DN that fails to be reported and restart the DN process. This parameter is not added to the CM Server configuration file by default. You need to manually add it.

Parameter type: integer.

Unit: seconds

Value range: 0 to 21474836. 0: disabled.

Default value: This parameter is enabled by default. The default value is (cm_server_num x agent_connect_timeout x agent_connect_retries + agent_heartbeat_timeout + 10).

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Faults may not be rectified in a timely manner.

cma_disconnect_to_cms_alarm_timeout

Parameter description: Specifies the timeout period for the CM Agent to disconnect from the primary CM Server. After the timeout, the cluster reports the ALM_AI_AbnormalConn alarm. When the duration of consecutive disconnections doubles the threshold, the ALM_AI_LongTimeAbnormalConn alarm is continuously reported.

Parameter type: integer.

Unit: seconds

Value range: 0 to 1000

  • 0: None of ALM_AI_AbnormalConn or ALM_AI_LongTimeAbnormalConn is reported.
  • 1 to 1000: indicates the duration when the CM Agent is disconnected from the primary CM Server.

Default value: 40

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: none

cm_server_arbitrate_delay_base_time_out

Parameter description: Specifies the basic delay duration for CM Server arbitration. If the primary CM Server is disconnected, the arbitration starts to be timed. If the disconnection duration exceeds the arbitration delay duration, a new primary CM Server will be selected. The arbitration delay duration is determined by the basic delay duration, the node index (server ID), and the incremental delay duration. The formula is as follows: Arbitration delay duration = Basic delay duration + Node index x Incremental delay duration.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 10

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too small, the CM Server disconnection fault is false positive. If the value is too large, the CM fault cannot be rectified in a timely manner.

cm_server_arbitrate_delay_incrememtal_time_out

Parameter description: Specifies the incremental delay duration for CM Server arbitration. If the primary CM Server is disconnected, the arbitration starts to be timed. If the disconnection duration exceeds the arbitration delay duration, a new primary CM Server will be selected. The arbitration delay duration is determined by the basic delay duration, the node index (server ID), and the incremental delay duration. The formula is as follows: Arbitration delay duration = Basic delay duration + Node index x Incremental delay duration.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 3

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too small, the CM Server disconnection fault is false positive. If the value is too large, the CM fault cannot be rectified in a timely manner.

cmserver_ha_connect_timeout

Parameter description: Specifies the time to wait before the attempt of CM Server to connect to other CM Servers times out.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2147483647

Default value: 2

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

cmserver_ha_heartbeat_timeout

Parameter description: Specifies the timeout interval for a CM Server to receive heartbeat signals from other CM Servers.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2147483647

Default value: 6

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large or too small, false negative and false positive may occur during fault detection.

cmserver_ha_status_interval

Parameter description: Specifies the interval between synchronizations of primary and standby CM Server status.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2147483647

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, CM fault detection and recovery cannot be performed in a timely manner. If the value is too small, the CPU load increases.

cmserver_demote_delay_on_etcd_fault

Parameter description: Specifies the delay within which CM Server switches from the primary state to the standby state due to unhealthy ETCD.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2147483647

Default value: 8

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too small, the ETCD fault detection result is false positive. If the value is too large, the CM fault cannot be rectified in a timely manner.

force_promote

Parameter description: Specifies whether CM Server enables forcible switchover (that is, when the cluster status is unknown, the basic functions of the cluster are available at the cost of data loss). This parameter applies to both CNs and DNs.

Parameter type: integer.

Unit: none

Value range: 0 to 1

  • 0: The forced switching logic function is disabled.
  • 1: The forcible switchover logic function is enabled.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: If you can accept the loss of some data caused by forcible service (system) switchover, enable this parameter when the service recovery has the highest priority.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

switch_rto

Parameter description: Specifies the delay for the forcible switchover of CM Server. When force_promote is set to 1 and a shard in the cluster does not have primary node, the system starts timing. After the delay, forcible switchover is executed.

Parameter type: integer.

Unit: seconds

Value range: 60 to 2147483647

Default value: 600

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too small, the database fault is false positive. If the value is too large, the fault cannot be rectified in a timely manner.

enable_finishredo_retrieve

Parameter description: Specifies whether to retrieve data of Xlogs that are cut off by redo logs after a forcible CM Server switchover. If this parameter is set to on, data is automatically retrieved after a forcible switchover.

Parameter type: Boolean

Unit: none

Value range:

  • on: Data is retrieved.
  • off: Data is not retrieved.

Default value: off

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Adjust the value according to the actual situation.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

backup_open

Parameter description: Specifies whether the CM runs in the standby cluster for DR.

Parameter type: integer

Unit: none

Value range: 0 to 3

  • 0: No DR relationship is established.
  • 1: The OceanStor Dorado-based DR relationship is established.
  • 2: The streaming replication-based DR relationship is established.
  • 3: The logical DR relationship is established.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Do not enable this parameter for clusters that are not standby clusters for DR. This parameter is internally called. You are advised not to modify it.

Risks and impacts of improper settings: Changing the value of this parameter may cause unexpected results in the cluster. Retain the default value.

install_type

Parameter description: Specifies the settings related to the standby cluster for DR to distinguish the cluster type.

Parameter type: integer

Unit: none

Value range: 0 to 2

  • 0: a cluster for which no DR relationship is established.
  • 1: an OceanStor Dorado-based cluster.
  • 2: a streaming-based cluster.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Do not enable this parameter for clusters that are not standby clusters for DR.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

enable_ssl

Parameter description: Specifies whether to enable SSL.

Parameter type: Boolean.

Unit: none

Value range:

  • on: The SSL certificate is enabled.
  • off: The SSL certificate is disabled.

Default value: off

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Disable this function by default. The CM component stores only the control information about clusters and does not involve user data. Therefore, disabling this function by default does not affect user data security.

Risks and impacts of improper settings: none

ssl_cert_expire_alert_threshold

Parameter description: Specifies the SSL certificate expiration alarm time. If the certificate expiration time is less than the value of this parameter, an alarm indicating that the certificate is about to expire is reported.

Parameter type: integer

Unit: day

Value range: 7–180

Default value: 90

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Adjust the value according to the actual situation.

Risks and impacts of improper settings: If the value is too small, alarms may not be rectified in a timely manner.

ssl_cert_expire_check_interval

Parameter description: Specifies the period for checking whether the SSL certificate expires.

Parameter type: integer

Unit: seconds

Value range: 0 to 2147483647

Default value: 86400 (that is, one day)

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Adjust the value according to the actual situation.

Risks and impacts of improper settings: If the value is too small, the CPU load increases. If the value is too large, alarms cannot be reported in a timely manner.

delay_arbitrate_timeout

Parameter description: Specifies the waiting time for a node in the same AZ as the primary DN to be promoted to primary after redo replay.

Parameter type: integer

Unit: seconds

Value range: 0 to 2147483647

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If the value is too large, DN faults may not be rectified in a timely manner.

dcf_heartbeat_timeout

Parameter description: Specifies the time to wait before the DCF instance heartbeat times out in the CM&DCF joint arbitration. If the primary DCF instance heartbeat times out, the DCF instance is unreachable by the CM and the CM will automatically trigger a DCF switchover. It takes effect only in DCF self-arbitration mode.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647. If this parameter is set to 0, heartbeat timeout detection is disabled for DCF instances in joint arbitration.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: After this function is disabled, the CM does not process the unreachable DCF instances. If a DCF instance is unreachable and abnormal, the CM cannot assist the arbitration. Before modifying this parameter, make sure you understand its meaning and fully verify the change in a test environment.

enable_dcf

Parameter description: Specifies the status of the DCF mode.

Parameter type: Boolean.

Unit: none

Value range:

  • on: The DCF mode is enabled.
  • off: The DCF mode is disabled.

Default value: off

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_type

Parameter description: Specifies whether to switch between ETCD and DCC modes.

Parameter type: integer

Unit: none

Value range: 0 to 1

  • 0: The ETCD mode is enabled.
  • 1: The DCC mode is enabled.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 in Table 2. The modification takes effect only after the cluster is restarted.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_log_level

Parameter description: Specifies the DDB log level.

Parameter type: string.

Unit: none

Value range:

  • "NONE": The log function is disabled. It cannot be used together with the following log levels.
  • "RUN_ERR|RUN_WAR|RUN_INF|DEBUG_ERR|DEBUG_WAR|DEBUG_INF|TRACE|PROFILE|OPER": Enable the log function. You can set this parameter to one or a combination of the preceding log levels. If two or more log levels are used together, separate them with vertical bars (|). The log level cannot be set to an empty character string.

Default value: "RUN_ERR|RUN_WAR|DEBUG_ERR|OPER|RUN_INF|PROFILE"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_log_backup_file_count

Parameter description: Specifies the maximum number of log files that can be saved.

Parameter type: integer

Unit: none

Value range: 1 to 100

Default value: 10

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_max_log_file_size

Parameter description: Specifies the maximum number of bytes in a log.

Parameter type: string.

Unit: none

Value range: The value of this parameter consists of digits and a unit. The value ranges from 1 to 1000, in MB.

Default value: "10M"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_log_suppress_enable

Parameter description: Specifies whether to enable the log suppression function.

Parameter type: integer

Unit: none

Value range: 0 to 1

  • 0: The log suppression function is disabled.
  • 1: The log suppression function is enabled.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_election_timeout

Parameter description: Specifies the DCC election timeout period.

Parameter type: integer

Unit: seconds

Value range: 1–600

Default value: 3

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_dcf_sync_nodes

Parameter description: Specifies the standby node list for DCC synchronous replication.

Parameter type: string.

Unit: none

Value range: a valid standby node list. The value can be in the following format:

ANY num_sync:node_id[, ...]

num_sync indicates the number of standby nodes to be synchronized and node_id indicates the sequence number of each standby node. Example: ddb_dcf_sync_nodes='ANY 1:2,3'.

Default value: ""

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

ddb_dcf_extreme_mode

Parameter description: Specifies the DCC log commit policy.

Parameter type: integer

Unit: none

Value range: 0 to 2

  • 0: maximum protection, that is, majority commit.
  • 1: maximum availability. When the standby node is faulty, the primary node can choose direct commit. When the standby node is normal, the primary node can choose majority commit.
  • 2: maximum performance, that is, local commit.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

alarm_ddb_unhealth_threshold

Parameter description: Specifies the threshold for reporting an alarm for an unhealthy DDB.

Parameter type: integer.

Unit: none

Value range: 0 to 2592000

Default value: 5

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

enable_e2e_rto

Parameter description: Specifies whether to enable the E2E RTO function. After this function is enabled, the zombie detection period and network detection timeout time are shortened. The CM can reach the E2E RTO value (RTO for a single instance: ≤ 10s; RTO for overlay faults: ≤ 30s).

Parameter type: integer.

Unit: none

Value range: 0 to 1

  • 0: The E2E RTO function is disabled.
  • 1: The E2E RTO function is enabled.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value. You can adjust the value as required.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

enable_synclist_single_inst

Parameter description: Specifies whether to reduce copies to one primary and zero standby. After this function is enabled, the number of copies will be reduced to one primary and zero standby. If the parameter is incorrectly set, the default value is used.

Parameter type: Boolean

Unit: none

Value range:

  • on: This function is enabled.
  • off: This function is disabled.

Default value: off

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value. If you need to change the value, contact Huawei technical support.

Risks and impacts of improper settings: If this parameter is enabled and all standby nodes are faulty, the primary node automatically switches to the local commit mode. In this case, if the primary node is faulty again, unrecoverable impacts may occur.

asyn_log_enable

Parameter description: Specifies whether to enable asynchronous logging. After this parameter is enabled, the CM Server starts asynchronous logging.

Parameter type: Boolean

Unit: none

Value range:

  • on: The CM Server starts asynchronous logging.
  • off: The CM Server does not start asynchronous logging but uses serial logging.

Default value: on

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If this parameter is disabled, logs may be lost.

asyn_log_max_buf_size

Parameter description: Specifies the size of the asynchronous log buffer. When asynchronous logs are stacked and the stacked logs exceed the buffer size, subsequent logs cannot be recorded.

Parameter type: integer.

Unit: KB

Value range: 1 to 1048576

Default value: 1024

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Adjust the value based on the memory and hard disk size.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

asyn_log_fault_solution

Parameter description: Specifies the asynchronous log processing solution after a log disk fault is identified. When the CM detects that a log disk is faulty or the asynchronous log buffer overflows, the CM processes asynchronous logs based on the configuration.

Parameter type: integer.

Unit: none

Value range: 0 to 2

  • 0: No extra processing is performed on logs. All logs are retained in the buffer until the buffer size reaches the upper limit. After the buffer size reaches the upper limit, no more logs are recorded.
  • 1: Logs are filtered. After a log disk fault is identified, only key logs, alarms, and logs at the ERROR level or higher are saved to the buffer until the buffer size reaches the upper limit. After the buffer size reaches the upper limit, no more logs are recorded.
  • 2: Logs are discarded. After a log disk fault is identified, only key logs and alarms are saved to the buffer until the buffer size reaches the upper limit. After the buffer size reaches the upper limit, no more logs are recorded.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Adjust the value based on the memory and hard disk size.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

enable_isolate

Parameter description: Specifies whether to isolate instances.

Parameter type: integer.

Unit: none

Value range: 0 to 1

  • 0: This function is disabled.
  • 1: This function is enabled. After this function is enabled, CM Server automatically isolates faulty instances.

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

barrier_restart_threshold

Parameter description: Specifies the interval of waiting for restarting the barrier of the standby cluster for DR. When the barrier of the standby cluster for DR is suspended for a period longer than the value of this parameter, the barrier is restarted.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2592000. 0 indicates that barrier restart is disabled.

Default value: 30

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Improper settings may cause inaccurate fault detection and delayed fault rectification.

enable_topology_network_arbitrate

Parameter description: Specifies whether to perform network topology arbitration. If this parameter is enabled, GaussDB performs arbitration based on the network topology. This parameter can be used only in quorum mode.

Parameter type: integer.

Unit: none

Value range:

  • 0: disabled.
  • 1: enabled. Once enabled, CM Server automatically performs arbitration based on the network topology.

Default value: 1

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

topology_network_arbitrate_wait_time

Parameter description: Specifies the waiting time for network topology data to become stable during network topology arbitration. If the network topology data changes within the period specified by this parameter, network topology arbitration is not performed. This parameter can be used only in quorum mode.

Parameter type: integer.

Unit: seconds

Value range: 5 to 600

Default value: 10

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

topology_network_collecting_failed_times

Parameter description: Specifies the number of consecutive network disconnections on the data plane. If the number of disconnections exceeds the value of this parameter, the data plane network topology is abnormal. The value must be the same as that of topology_network_collecting_failed_times set for the CM Agent. This parameter can be used only in quorum mode.

Parameter type: integer.

Unit: none

Value range: 3 to 50

Default value: 5

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

topology_network_stable_cn_percent

Parameter description: Specifies the percentage of remaining CNs that can be loaded on the data plane network topology. The network arbitration module calculates the minimum number of reserved CNs based on this parameter. The minimum number of retained CNs is the number of all CNs multiplied by the value of this parameter. If the calculated number is less than 1, the value 1 is used. This parameter can be used only in quorum mode.

Parameter type: integer.

Unit: none

Value range: 0 to 100

Default value: 50

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

topology_network_check_max_cn_count

Parameter description: Specifies the maximum number of CNs in a cluster supported by data plane network topology detection. If the number of CNs exceeds the value of this parameter, data plane network topology arbitration is not performed. If this parameter is set to 0, network topology arbitration is disabled. This parameter can be used only in quorum mode.

Parameter type: integer.

Unit: none

Value range: 0 to 256

Default value: 16

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

hardware_max_cn_delete_threshold

Parameter description: Specifies the maximum threshold for removing CNs due to hardware faults. The value is rounded down.

Parameter type: integer.

Unit: %

Value range: 0 to 99

  • 0: CNs are not removed.
  • 1–99: indicates the percentage of CNs to be removed. At least one available CN must be retained.

Default value: 50

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cluster_starting_aribt_delay

Parameter description: Specifies the time that CM Server waits for the static primary DN to be promoted to primary during cluster startup.

Parameter type: integer.

Unit: seconds

Value range: 1 to 2592000

Default value: 180

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 1 and method 2 in Table 2.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cluster_unavailable_alarm_timeout

Parameter description: Specifies the timeout period for a cluster in the unavailable state. After the timeout, the cluster reports the ALM_AI_ClusterUnavailable alarm.

Parameter type: integer.

Unit: seconds

Value range: 0 to 1000

  • 0: This alarm is not reported.
  • 1–1000: indicates the time when the cluster is in an unavailable state.

Default value: 40

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: none

cluster_degrade_alarm_timeout

Parameter description: Specifies the timeout period for a cluster to be in the Degrade state. After the timeout, the cluster reports the ALM_AI_ClusterDegrade alarm.

Parameter type: integer.

Unit: seconds

Value range: 0 to 1000

  • 0: This alarm is not reported.
  • 1–1000: indicates the time when the cluster is in the Degrade state.

Default value: 40

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: none

max_frequency_heal_timeout

Parameter description: The ALM_AI_ClusterHealFrequent alarm is triggered if the cluster is healed for 10 times or more within this period.

Parameter type: integer.

Unit: seconds

Value range: 0 to 1000

  • 0: This alarm is not reported.
  • 1 to 1000: indicates the time range for continuously triggering the healing process.

Default value: 300

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: none

cn_auto_repair_max_concurrency

Parameter description: Specifies the maximum number of CNs that can be concurrently added back.

Parameter type: integer.

Unit: none

Value range: 0 to 256. 0 indicates that the number of CNs concurrently added back is the same as the number of normal CNs in the cluster but cannot be greater than 10.

Default value: 0

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cn_auto_repair_timeout

Parameter description: Specifies the timeout period for adding CNs back. If a CN fails to be added back repeatedly in a period longer than this threshold and the number of attempt failures exceeds this retry threshold, it will be abandoned from automatic re-addition.

Parameter type: integer.

Unit: none

Value range: 0 to 2147483647

Default value: 1800

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cn_auto_repair_retry_times

Parameter description: Specifies the number of CN re-addition retries. If a CN fails to be added back repeatedly in a period longer than the timeout threshold and the number of attempt failures exceeds this retry threshold, it will be abandoned from automatic re-addition. Though it is abandoned, if you adjust the value of this threshold, automatic re-addition of the faulty CN will start again.

Parameter type: integer.

Unit: none

Value range: 0 to 2147483647

Default value: 3

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

cn_dn_disconnect_to_delete_time

Parameter description: Specifies the number of times that a CN fails to check SQL statements on all primary DNs. When the number of failures exceeds the value of this parameter, the CN is removed.

Parameter type: integer.

Unit: none

Value range: 1 to 600

Default value: 20

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

majority_standby_lock_timeout

Parameter description: Specifies the timeout interval for locking the majority of standby nodes. The cluster enters the leader election (arbitration) process and locks the majority of standby nodes. When the primary node is faulty, the arbitration process is blocked until this timeout period expires. After the timeout period expires, the original primary node is stopped and the arbitration process is resumed.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647. The value 0 indicates that the function is disabled.

Default value: 120

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.

replica_reduce_delay_time

Parameter description: Specifies the delay time for reducing copies. If the majority of DNs are in the unknown state, the copy reduction operation is triggered only after the detected state persists for a period of time specified by this parameter. If the majority of DNs are in the building, need_repair, or starting state, the copy reduction operation is triggered only after the detected state persists for a period of time five times the specified delay.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 12

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If this parameter is set to a small value, the probability of incorrect copy reduction increases in a short period of time due to faults such as network disconnection. If this parameter is set to a large value, the cluster is unavailable for a long time when the majority of nodes are faulty. Before modifying this parameter, make sure you understand its meaning and fully verify the change in a test environment.

replica_increase_delay_time

Parameter description: Specifies the delay time for adding copies. When a copy is recovered and can be added back (that is, the copy status is normal and the log synchronization rate is greater than or equal to 99%), the automatic copy addition is triggered only after a delay specified by this parameter. This parameter is used to prevent resource flapping caused by immediate copy addback after copy reduction.

Parameter type: integer.

Unit: seconds

Value range: 0 to 2147483647

Default value: 60

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: Retain the default value.

Risks and impacts of improper settings: If this parameter is set to a small value, resource flapping caused by immediate copy addition after copy reduction may occur. If this parameter is set to a large value, the time for adding copies back after they are recovered is prolonged. Before modifying this parameter, make sure you understand its meaning and fully verify the change in a test environment.

dr_dest_name

Parameter description: Specifies the target clusters to which logs can be synchronized from the current cluster. This parameter is valid only when the cluster is deployed in a single-node system. In addition, you do not need to reload the parameter after setting this parameter.

Parameter type: string

Unit: none

Value range: a valid target cluster instance ID.

Default value: ""

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3. After this parameter is set, you do not need to reload the parameter.

Setting suggestion: This parameter is internally called. You are advised not to modify it.

Risks and impacts of improper settings: Changing the value of this parameter may cause unexpected results in the cluster. Retain the default value.

hadr_replconninfo_config_mode

Parameter description: Specifies the DR type of the current database instance.

Parameter type: string

Unit: none

Value range: "local_file" or "cluster_manager"

Default value: "local_file"

Setting method: This parameter is a CM parameter. For details about how to modify this parameter, see method 2 in Table 3.

Setting suggestion: This parameter is internally called. You are advised not to modify it.

Risks and impacts of improper settings: Changing the value of this parameter may cause unexpected results in the cluster. Retain the default value.