Cost-based Vacuum Delay
This feature is designed to reduce the I/O impact of maintenance operations such as VACUUM and ANALYZE in high-concurrency databases. The cost-based vacuum delay mechanism enables administrators to balance resource allocation among maintenance tasks and normal service operations. This feature provides the following functions:
- Non-critical delay: Maintenance operations do not need to be completed immediately and can be executed in the backend.
- Resource isolation: Maintenance tasks are prevented from occupying too many I/O resources, ensuring service query performance.
Certain VACUUM operations hold critical locks and should be complete as quickly as possible. In GaussDB, cost-based vacuum delays do not take effect during such operations. To avoid uselessly long delays in such cases, the actual delay is the larger of the two calculated values:
- vacuum_cost_delay x accumulated_balance/vacuum_cost_limit
- vacuum_cost_delay x 4
Context
During the execution of the ANALYZE | ANALYSE and VACUUM statements, the system maintains an internal counter that keeps track of the estimated cost of the various I/O operations that are performed. When the accumulated I/O cost reaches the threshold specified by vacuum_cost_limit, the thread that performs the maintenance operation sleeps for the time specified by vacuum_cost_delay. After the sleep ends, the counter is reset, and the operation continues. This feature is disabled by default. You need to set vacuum_cost_delay to a non-zero value to enable it.
vacuum_cost_delay
Parameter description: VACUUM starts the backend worker thread to vacuum dead tuples in the data table, which conflicts with the worker thread. If vacuum_cost_delay is set to the value of vacuum_cost_limit to control the impact of VACUUM on services, the VACUUM thread hibernates the time specified by vacuum_cost_delay and allocates resources to worker threads for execution to ensure that services are not blocked by backend VACUUM.
Parameter type: integer.
Unit: milliseconds
Value range: 0 to 100. The value 0 indicates that the cost-based vacuum delay feature is disabled, and a positive value indicates that the cost-based vacuum delay feature is enabled. In many systems, the effective resolution of the hibernation time is 10 milliseconds. Therefore, setting vacuum_cost_delay to a value that is not an integer multiple of 10 has the same effect as setting it to the next higher multiple of 10.
Default value: 1
Setting method: This is a USERSET parameter. Set it based on instructions provided in Table 1.
Setting suggestion: This parameter is usually set to a small value, such as 10ms or 20ms. Adjusting vacuum's resource consumption is best done by changing other vacuum cost parameters.
Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.
vacuum_cost_page_hit
Parameter description: Specifies the estimated cost for VACUUM to clean up data pages hit in a buffer.
Parameter type: integer.
Unit: none
Value range: 0 to 10000
Default value: 1
Setting method: This is a USERSET parameter. Set it based on instructions provided in Table 1.
Setting suggestion: Retain the default value.
Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.
vacuum_cost_page_miss
Parameter description: Specifies the estimated cost for VACUUM to clean up data pages that do not hit in a buffer.
Parameter type: integer.
Unit: none
Value range: 0 to 10000
Default value: 10
Setting method: This is a USERSET parameter. Set it based on instructions provided in Table 1.
Setting suggestion: Retain the default value.
Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.
vacuum_cost_page_dirty
Parameter description: Specifies the cost of VACUUM cleanup dirty pages. If the data page to be cleaned up is a clean page, VACUUM cleanup generates an extra cost of flushing dirty pages to disks. You can set this parameter to specify the cost of VACUUM cleanup dirty pages.
Parameter type: integer.
Unit: none
Value range: 0 to 10000
Default value: 20
Setting method: This is a USERSET parameter. Set it based on instructions provided in Table 1.
Setting suggestion: Retain the default value.
Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.
vacuum_cost_limit
Parameter description: Specifies the cost limit. The vacuum thread will hibernate if this limit is exceeded. When the execution cost of the VACUUM thread reaches vacuum_cost_limit, the thread sleeps for the time specified by vacuum_cost_delay.
Parameter type: integer.
Unit: none
Value range: 1 to 10000
Default value: 1000
Setting method: This is a USERSET parameter. Set it based on instructions provided in Table 1.
Setting suggestion: Retain the default value. A larger value indicates a smaller I/O frequency limit of the VACUUM, a lower probability of entering the hibernation, more efficient VACUUM, and a greater impact on service I/Os.
Risks and impacts of improper settings: Change the parameter value after fully understanding the parameter meaning and verifying it through testing.
vacuum_defer_cleanup_age
Parameter description: Specifies the delay for the VACUUM operation to clear invalid row-store table records. The delay is calculated based on the number of executed transactions. You can set the value of vacuum_defer_cleanup_age to control the number of delayed transactions. That is, the VACUUM and VACUUM FULL operations do not clear a deleted tuple immediately. Instead, they clear and delete the tuple only after a certain number of transactions have been processed.
Parameter type: integer.
Unit: none
Value range: 0 to 1000000. 0 indicates no delay.
Default value: 0
Setting method: This is a SIGHUP parameter. Set it based on instructions provided in Table 1.
Setting suggestion: Retain the default value.
Risks and impacts of improper settings: If the value is too large, VACUUM and VACUUM FULL cannot be performed in a timely manner.