Registering a Device on ROMA Connect
Overview
After a device is registered on ROMA Connect, a unique ID and key are allocated to the device so that the device can access ROMA Connect.
Prerequisites
- ROMA Connect can communicate with the parking lot devices and the parking lot management system. If the ROMA Connect instances communicate with each other through the public network, an elastic IP address (EIP) must be bound to each instance.
- Parking lot devices include parking space sensors and entrance and exit gate devices. The configuration processes are similar. The following describes how to configure parking space sensors.
Procedure
- Create an integration application.
- Log in to the ROMA Connect console. On the Instances page, click View Console next to a specific instance.
- In the navigation pane on the left, choose Integration Applications. In the upper right corner of the page, click Create Integration Application.
- In the dialog box displayed, set Name and click OK.
- Define products on ROMA Connect based on the capability model of parking space sensors.
- In the navigation pane on the left, choose LINK > Product Management. On the page displayed, click Create Product in the upper right corner.
- In the Create Product dialog box, set product parameters and click OK.
Table 1 Product parameters Parameter
Description
Product Type
If the parking lot device is directly connected to ROMA Connect through the network, select Common.
Protocol Type
Set this parameter to MQTT because the parking lot device connects to ROMA Connect through the integrated MQTT client.
Integration application
Select the integration application created in 1.
Product Template
This parameter is not set in this practice.
Product Name
Enter the name of the product. It can be user-defined.
Manufacturer Name
Enter the manufacturer name of the parking lot device.
Manufacturer ID
Enter the manufacturer ID of the parking lot device.
Product Model
Enter the product model of the parking lot device.
Device Type
Select Default Type as the type of the access device.
Model Version
Enter the model version of the device. This parameter is not set in this practice.
Description
Enter a brief description of the product.
- On the Product Management page, click the Products tab and click the name of the product created in 2.b to access the product details page.
- On the Thing Model tab page, click Create.
- In the Create Thing Model Service dialog box, set thing model service parameters and click OK.
Table 2 Thing model service configuration Parameter
Description
Name
Name of the thing model service. Set this parameter as required, for example, ParkingStatus.
Status
This parameter specifies whether to enable the thing model service. Retain the default value Enabled.
Description
Enter a brief description of the thing model service.
- Select the thing model service created in 2.e, and click Create on the Attributes tab page of the thing model service on the right.
- In the Create Attribute dialog box, set attribute parameters and click OK.
The following uses the configuration of the parking space sensor as an example. The parking space sensor reports the following information:
- deviceId indicates the physical identifier of the device. The data type is String.
- status indicates the parking space attribute. The data type is String. The value 0 indicates vacant, and 1 indicates occupied.
Table 3 Service attribute configuration Parameter
deviceId Description
status Description
Name
Name of the attribute parameter reported by the device. Set this parameter to deviceId.
Name of the attribute parameter reported by the device. Set this parameter to status.
Data Type
Select String as the data type of the attribute parameter reported by the device.
Select String as the data type of the attribute parameter reported by the device.
Mandatory
This parameter specifies whether the attribute must be reported by a device. Retain the default value, that is, the attribute must be reported by the device.
This parameter specifies whether the attribute must be reported by a device. Retain the default value, that is, the attribute must be reported by the device.
Description
Enter a brief description of the attribute.
Enter a brief description of the attribute.
Min. Value
Enter the minimum value of the thing model service attribute.
Enter the minimum value of the thing model service attribute.
Max. Value
Enter the maximum value of the thing model service attribute.
Enter the maximum value of the thing model service attribute.
Step
Enter the step of the attribute.
Enter the step of the attribute.
Unit
Enter the unit of the attribute.
Enter the unit of the attribute.
- Register a device on ROMA Connect.
Each parking lot device must be registered on ROMA Connect.
- In the navigation pane on the left, choose LINK > Device Management. On the page displayed, click Create Device in the upper right corner.
- In the Create Device dialog box, set device parameters and click OK.
Table 4 Device configuration Parameter
Description
Device Name
Enter the name of the device.
Integration Application
Select the integration application created in 1.
Associated Product
Select the product created in 2.
Device ID
Enter the physical identifier of the device, such as the IMEI and MAC address of the device.
Password
Enter the access password of the device. If you do not specify this parameter, the system automatically generates a value.
Confirm Password
Enter the password for confirmation. If you do not set this parameter, the system automatically generates one.
Status
This parameter specifies whether to enable the device. The device can connect to ROMA Connect only after being enabled. Retain the default value Enabled.
Device Tag
Add tags for the device to facilitate search.
Description
Enter a brief description of the device.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.