Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-50220 Error Rate of TCP Packet Receiving Exceeds the Threshold
Updated on 2024-04-11 GMT+08:00

ALM-50220 Error Rate of TCP Packet Receiving Exceeds the Threshold

Alarm Description

The system checks the rate of TCP packet receiving errors every 30 seconds. This alarm is generated when the error rate exceeds the threshold (5% by default).

This alarm is cleared when the error rate is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

50220

Critical

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster or system for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Trigger Condition

Specifies the threshold for triggering the alarm.

Impact on the System

The task fails or data is lost.

Possible Causes

The network is faulty, so data cannot be sent.

Handling Procedure

  1. Log in to the host where the faulty node is deployed as user root and run ping IP addresses of all Doris nodes to check whether the peer host can be pinged.

    • If yes, go to 4.
    • If no, go to 2.

  2. Contact the network administrator to restore the network.
  3. Wait for a while and check whether the alarm is cleared in the alarm list.

    • If yes, no further action is required.
    • If no, go to 4.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select Doris for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.