GaussDB(DWS) Result Table
Function
DLI outputs the Flink job output data to GaussDB(DWS). GaussDB(DWS) database kernel is compliant with PostgreSQL. The PostgreSQL database can store data of more complex types and delivers space information services, multi-version concurrent control (MVCC), and high concurrency. It applies to location applications, financial insurance, and e-commerce.
GaussDB(DWS) is an online data processing database based on the cloud infrastructure and platform and helps you mine and analyze massive sets of data.
Prerequisites
- Ensure that you have created a GaussDB(DWS) cluster using your account.
For details about how to create a GaussDB(DWS) cluster, see "Creating a Cluster" in Data Warehouse Service Management Guide.
- A GaussDB(DWS) database table has been created.
- An enhanced datasource connection has been created for DLI to connect to GaussDB(DWS) clusters, so that jobs can run on the dedicated queue of DLI and you can set the security group rules as required.
Syntax
1 2 3 4 5 6 7 8 9 10 11 12 13 |
create table dwsSink (
attr_name attr_type
(',' attr_name attr_type)*
(','PRIMARY KEY (attr_name, ...) NOT ENFORCED)
)
with (
'connector.type' = 'gaussdb',
'connector.url' = '',
'connector.table' = '',
'connector.driver' = '',
'connector.username' = '',
'connector.password' = ''
);
|
Parameters
Parameter |
Mandatory |
Description |
---|---|---|
connector.type |
Yes |
Connector type. Set this parameter to gaussdb. |
connector.url |
Yes |
JDBC connection address. The format is jdbc:postgresql://${ip}:${port}/${dbName}. |
connector.table |
Yes |
Name of the table to be operated. If the GaussDB(DWS) table is in a schema, the format is schema\".\"Table name. For details, see the Example. |
connector.driver |
No |
JDBC connection driver. The default value is org.postgresql.Driver. |
connector.username |
No |
Database authentication user name. This parameter must be configured in pair with connector.password. |
connector.password |
No |
Database authentication password. This parameter must be configured in pair with connector.username. |
connector.write.mode |
No |
Data write mode. The value can be copy, insert, or upsert. The default value is upsert. This parameter must be configured depending on primary key.
Note: GaussDB(DWS) does not support the update of distribution columns. The primary keys of columns to be updated must cover all distribution columns defined in the GaussDB(DWS) table. |
connector.write.flush.max-rows |
No |
Maximum rows allowed for data flush. If the data size exceeds the value, data flush is triggered. The default value is 5000. |
connector.write.flush.interval |
No |
Data flush period. Data flush is triggered periodically. The format is {length value}{time unit label}, for example, 123ms, 321s. The supported time units include d, h, min, s, and ms (default unit). If this parameter is not set, the value is not updated based on the interval by default. |
connector.write.max-retries |
No |
Maximum number of attempts to write data. The default value is 3. |
connector.write.merge.filter-key |
No |
Column to be merged. This parameter takes effects only when PRIMARY KEY is configured and connector.write.mode is set to copy. |
connector.write.escape-string-value |
No |
Whether to escape values of the string type. The default value is false. |
Precautions
None
Example
- If you use the gsjdbc4 driver for connection, set connector.driver to org.postgresql.Driver. You can omit this parameter because the gsjdbc4 driver is the default one.
- Write data to GaussDB(DWS) in upsert mode.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
create table dwsSink( car_id STRING, car_owner STRING, car_brand STRING, car_speed INT ) with ( 'connector.type' = 'gaussdb', 'connector.url' = 'jdbc:postgresql://xx.xx.xx.xx:8000/xx', 'connector.table' = 'car_info', 'connector.username' = 'xx', 'connector.password' = 'xx', 'connector.write.mode' = 'upsert', 'connector.write.flush.interval' = '30s' );
Create table dwsSource with data fetched from GaussDB(DWS) table test that is in a schema named ads_game_sdk_base:CREATE TABLE ads_rpt_game_sdk_realtime_ada_reg_user_pay_mm ( ddate DATE, dmin TIMESTAMP(3), game_appkey VARCHAR, channel_id VARCHAR, pay_user_num_1m bigint, pay_amt_1m bigint, PRIMARY KEY (ddate, dmin, game_appkey, channel_id) NOT ENFORCED ) WITH ( 'connector.type' = 'gaussdb', 'connector.url' = 'jdbc:postgresql://xx.xx.xx.xx:8000/dws_bigdata_db', 'connector.table' = 'ads_game_sdk_base\".\"test', 'connector.username' = 'xxxx', 'connector.password' = 'xxxxx', 'connector.write.mode' = 'upsert', 'connector.write.flush.interval' = '30s' );
- Write data to GaussDB(DWS) in upsert mode.
- If you use the gsjdbc200 driver for connection, set connector.driver to com.huawei.gauss200.jdbc.Driver.
Create table dwsSource with data fetched from GaussDB(DWS) table test that is in a schema named ads_game_sdk_base:
create table dwsSink( car_id STRING, car_owner STRING, car_brand STRING, car_speed INT ) with ( 'connector.type' = 'gaussdb', 'connector.table' = 'ads_game_sdk_base\".\"test', 'connector.driver' = 'com.huawei.gauss200.jdbc.Driver', 'connector.url' = 'jdbc:gaussdb://xx.xx.xx.xx:8000/xx', 'connector.username' = 'xx', 'connector.password' = 'xx', 'connector.write.mode' = 'upsert', 'connector.write.flush.interval' = '30s' );
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.