Updated on 2024-08-19 GMT+08:00

BlackHole

Function

The BlackHole connector allows for swallowing all input records. It is designed for high-performance testing and UDF output. It is not a substantive sink. The BlackHole result table is a built-in connector.

For example, if an error is reported when you register a result table of another type, but you are not sure whether it is caused by a system fault or an invalid setting of the WITH parameter for the result table, you can change the value of connector to blackhole and click Run. If no error is reported, the system is normal. You must check the settings of the WITH parameter.

Table 1 Supported types

Type

Description

Supported Table Types

Result table

Caveats

  • When you create a Flink OpenSource SQL job, set Flink Version to 1.15 in the Running Parameters tab. Select Save Job Log, and specify the OBS bucket for saving job logs.
  • Storing authentication credentials such as usernames and passwords in code or plaintext poses significant security risks. It is recommended using DEW to manage credentials instead. Storing encrypted credentials in configuration files or environment variables and decrypting them when needed ensures security. For details, see .

Syntax

create table blackhole_table (
 attr_name attr_type (',' attr_name attr_type) *
) with (
 'connector' = 'blackhole'
);

Parameter Description

Table 2 Parameter

Parameter

Mandatory

Default Value

Data Type

Description

connector

Yes

None

String

Connector to be used. Set this parameter to blackhole.

Example

The DataGen source table generates data, and the BlackHole result table receives the data.

create table datagenSource (
 user_id string,
 user_name string,
 user_age int
) with (
 'connector' = 'datagen',
 'rows-per-second'='1'
);
create table blackholeSink (
 user_id string,
 user_name string,
 user_age int
) with (
 'connector' = 'blackhole'
);
insert into blackholeSink select * from datagenSource;