Updated on 2025-11-21 GMT+08:00

Integration Management

This API is used by users to access the alarm data.

Function

This API is used for tenants to integrate their own monitoring systems into COC based on certain standards. After the integration, alarms are reported to the COC alarm center in the standard format.

URI

POST /v1/event/huawei/custom/{integration_key}

Table 1 URI parameters

Parameter

Mandatory

Type

Description

integration_key

Yes

String

Integration ID.

Minimum length: 1 character

Maximum length: 255 characters

Request Parameters

Table 2 Request body parameters

Parameter

Mandatory

Type

Description

alarmId

Yes

String

Alarm id

Minimum length: 1 character

Maximum length: 255 characters

alarmName

Yes

String

Alarm name

Minimum length: 1 character

Maximum length: 255 characters

alarmLevel

Yes

String

Alarm severity. The value can be Critical, Major, Minor, or Info.

Minimum length: 1 character

Maximum length: 255 characters

The value can be:

  • Critical
  • Major
  • Minor
  • Info

time

Yes

Long

Time when an alarm is generated

nameSpace

Yes

String

Namespace of a service

Minimum length: 1 character

Maximum length: 255 characters

regionId

No

String

ID of the region where the alarm is generated

Minimum length: 0 character

Maximum length: 255 characters

applicationId

Yes

String

Application ID

Minimum length: 1 character

Maximum length: 255 characters

resourceName

No

String

Resource name

Minimum length: 0 character

Maximum length: 255 characters

resourceId

No

String

Resource ID

Minimum length: 0 character

Maximum length: 255 characters

alarmDesc

Yes

String

Alarm description

Minimum length: 1 character

Maximum length: 255 characters

URL

No

String

Original alarm URL

Minimum length: 0 character

Maximum length: 255 characters

alarmStatus

No

String

Alarm status. The value can be alarm (in alarm) or ok (alarm restored).

Minimum length: 0 character

Maximum length: 255 characters

The value can be:

  • alarm
  • ok

alarmSource

Yes

String

Alarm Sources

Minimum length: 1 character

Maximum length: 255 characters

additional

No

Object

Supplementary information about the alarm

Response Parameters

Status code: 200

Table 3 Response body parameters

Parameter

Type

Description

provider_code

String

Service ID.

Default value: 049

Minimum length: 0 character

Maximum length: 256 characters

error_code

String

Request response code. The value ranges from 0000 to 9999. The value is 0 in normal cases.

Default: 0

Minimum length: 0 character

Maximum length: 256 characters

error_msg

String

Request response description.

Minimum length: 0 character

Maximum length: 256 characters

Request Example

https://{Endpoint}/v1/event/huawei/custom/{integration_key}

{
  "alarmId" : "18cfxxxxxxxxxx0f8",
  "alarmName": "CPU Usage Exceeding Threshold",
  "alarmLevel" : "Critical",
  "time" : 1709118444540,
  "nameSpace" : "shanghai",
  "regionId" : "eu-west-0",
  "applicationId" : "18cfa0a5ef8d",
  "resourceName" : "machine-1",
  "resourceId" : "18cxxxxxxxxxxxxff68625",
  "alarmDesc" : "string",
  "URL" : "https://example.com",
  "alarmStatus" : "alarm",
  "alarmSource" : "coc",
  "additional" : { }
}

Response Example

Status code: 200

The request is successful.

{
  "error_code" : "COC.00000000",
  "error_msg" : "success",
  "data" : null,
  "provider_code" : "049"
}

Status code: 400

Incorrect request body.

{
  "error_code" : "COC.00000001",
  "error_msg" : "alarmName must not be null | alarmId must not be null",
  "data" : null,
  "provider_code" : "049"
}

Status code: 401

Authentication error.

{
  "error_code" : "common.01010001",
  "error_msg" : "Token missing or invalid.",
  "data" : null,
  "provider_code" : "049"
}

Status Code

Status Code

Description

200

Request succeeded.

400

Incorrect request body.

401