Preparations
Before enabling Direct Connect, you need to make full preparations, including selecting an appropriate Direct Connect location and consulting the carrier about the site survey.
Selecting a Direct Connect Location
- Distance to your data center
Select a location nearest to your data center to reduce network latency. The telecom carriers and bandwidth capabilities vary at different locations.
- Carrier
Select a carrier that can best meet your service requirements. Generally, you can choose one from carriers such as China Unicom, China Telecom, and China Mobile.
- Port
Decide what type of port you want to use, an optical port or electrical port.
- Optical port: The carrier directly provides an optical path on the transmission network for the end user. The optical port speed is infinite depends on auto-negotiation rate of optical modules at both ends, for example, 1GE, 10GE, 40GE, and 100GE.
- Electrical port: Generally, RJ45 ports are used. The carrier uses an optical transceiver to convert electrical signals to optical signals required on the transmission network. According to industry standards, this type of port is used when the bandwidth is less than 100 Mbit/s.
- Currently, 1GE and 10GE single-mode optical ports can transmit data up to 10 km. If you need an optical port that can transmit data for more than 10 km, or you need a 40GE or 100GE port, you need to purchase optical modules by yourself.
- Ensure that the leased line provider can provide optical fibers to connect to Direct Connect devices.
- No O/E conversion device is allowed on HUAWEI CLOUD. Ensure that the leased line provider uses the correct line type to connect to Direct Connect devices.
Table 1 lists available Direct Connect locations. To obtain detailed equipment room address of a location, contact the Direct Connect manager or submit a service ticket.
|
Geographic Region |
City |
Region |
Location |
IDC |
|---|---|---|---|---|
|
Chinese mainland |
Beijing |
CN North-Beijing4 |
Langfang-Guangyang-Huawei |
Huawei |
|
Beijing-Tongzhou-Huitian |
Huitian |
|||
|
Beijing-Yizhuang-Centrin |
Centrin Data Systems |
|||
|
Beijing-Yizhuang-Yatai |
Yatai Zhongli |
|||
|
Chinese mainland |
Beijing |
CN North-Ulanqab1 |
Ulanqab-Jining-Huawei |
Huawei |
|
Chinese mainland |
Shanghai |
CN East-Shanghai2 |
Shanghai-Pudong-GDS |
GDS |
|
Shanghai-Baoshan-Baoxin |
Baoxin |
|||
|
Shanghai-Jiading-Sinnet |
Sinnet |
|||
|
Suzhou |
CN East-Shanghai1 |
Suzhou-Kunshan-GDS |
GDS |
|
|
Suzhou-Wuzhong-Guoke |
China Unicom |
|||
|
Guangzhou |
CN South-Guangzhou |
Guangzhou-Huangpu-Huaxinyuan |
Bigone |
|
|
Guangzhou-Fanyu-University town |
Bigone |
|||
|
Guiyang |
CN Southwest-Guiyang1 |
Guiyang-Gui'an-Mobile |
China Mobile |
|
|
Guiyang-Gui'an-Unicom |
China Unicom |
|||
|
Asia Pacific |
Hong Kong |
CN-Hong Kong |
Hong Kong-Sha Tin-Telecom |
China Telecom |
|
Hong Kong-Sai Kung-Mobile |
China Mobile |
|||
|
Bangkok |
AP-Bangkok |
Bangkok-NTT |
NTT |
|
|
Bangkok-TRUE |
TRUE |
|||
|
Singapore |
AP-Singapore |
Singapore-DataPro |
Equinix |
|
|
Singapore-Global Switch |
Global Switch |
|||
|
South Africa |
Johannesburg |
AF-Johannesburg |
Johannesburg-Vodacom |
Vodacom |
|
Johannesburg-MTN |
MTN |
|||
|
Johannesburg-IS Parklands |
Internet Solutions Parklands |
|||
|
Johannesburg-Teraco |
Teraco |
|||
|
Latin America |
Mexico |
LA-Mexico City1 |
Mexico-Ixtlahuaca |
Ixtlahuaca |
|
Sao Paulo |
LA-Sao Paulo1 |
Sao Paulo-Telefonica TB1 |
Telefonica TB1 |
|
|
Sao Paulo-Equinix |
Equinix |
|||
|
Sao Paulo-ODATA |
OData |
|||
|
Santiago |
LA-Santiago |
Santiago-Paine |
Paine |
|
|
Santiago-Claro |
Claro |
Site Survey by the Carrier
After you select a location, contact the carrier for a site survey.
- Consult the carrier about the way to access the cloud.
You can contact the Direct Connect manager or submit a service ticket to obtain the detailed address of the equipment room.
- Submit an application to HUAWEI CLOUD for conducting a site survey in the equipment room.
The application must include the name, ID card number, contact information of the personnel who will go to the equipment room for the site survey.
If the site survey can be completed at the carrier's meet-me room, you do not need to submit an application.
- After the application is approved, HUAWEI CLOUD will assist the carrier in entering the equipment room for completing the site survey within two working days.
- Request the carrier to carry out the site survey and confirm the fees, including the costs of:
- Port (paid to HUAWEI CLOUD) and one-time setup (free for now)
- Leased line (paid to the carrier)
- In-building cabling