Querying an Alarm Rule
Function
This API is used to query an alarm rule based on the alarm rule ID.
URI
GET /V1.0/{project_id}/alarms/{alarm_id}
- Parameter description
Table 1 Parameter description Parameter
Mandatory
Description
project_id
Yes
Specifies the project ID.
For details about how to obtain the project ID, see Obtaining a Project ID.
alarm_id
Yes
Specifies the alarm rule ID.
- Example
GET https://{Cloud Eye endpoint}/V1.0/{project_id}/alarms/al1441967036681YkazZ0deN
Request
None
Response
- Response parameters
Parameter
Type
Description
Array of objects
Specifies the list of alarm objects.
For details, see Table 2.
Table 2 metric_alarms field data structure description Parameter
Type
Description
alarm_name
String
Specifies the alarm rule name.
alarm_description
String
Provides supplementary information about the alarm rule.
Array of objects
Specifies the alarm metric.
For details, see Table 3.
Array of objects
Specifies the alarm triggering condition.
For details, see Table 8.
alarm_enabled
Boolean
Specifies whether to enable the alarm rule.
alarm_level
Integer
Specifies the alarm severity. Possible values are 1, 2, 3 and 4, which indicates critical, major, minor, and informational, respectively.
alarm_type
String
Specifies the alarm type.
- For event alarms, the alarm type is EVENT.SYS (system event) or EVENT.CUSTOM (custom event).
- When an alarm is generated for a resource group, the alarm type is RESOURCE_GROUP.
- When an alarm is generated for a specified resource, the alarm type is MULTI_INSTANCE.
alarm_action_enabled
Boolean
Specifies whether to enable the action to be triggered by an alarm.
Array of objects
Specifies the action triggered by an alarm.
For details, see Table 5.
Array of objects
Specifies the action to be triggered after the alarm is cleared.
For details, see Table 6.
Array of objects
Specifies the action triggered by data insufficiency.
For details, see Table 7.
alarm_action_begin_time
String
Specifies the time when an alarm rule starts to take effect. Notifications are sent only within the validity period of the alarm rule.
For example, if alarm_action_begin_time is set to 08:00 and alarm_action_end_time is set to 20:00, notifications are sent only from 08:00 to 20:00.
alarm_action_end_time
String
Specifies the time when an alarm rule stops to take effect.
For example, if alarm_action_begin_time is set to 08:00 and alarm_action_end_time is set to 20:00, notifications are sent only from 08:00 to 20:00.
alarm_id
String
Specifies the alarm rule ID.
update_time
long
Specifies the time when the alarm status changed. The value is a UNIX timestamp and the unit is ms.
alarm_state
String
Specifies the alarm status. The value can be:
- ok: The alarm status is normal.
- alarm: An alarm is generated.
- insufficient_data: The required data is insufficient.
enterprise_project_id
String
Specifies the enterprise project ID.
NOTE:This parameter is available in the CN East-Shanghai1 region.
- Value all_granted_eps indicates all enterprise projects.
- Value 0 indicates the default enterprise project default.
Table 3 metric field data structure description Parameter
Type
Description
namespace
String
Query the namespace of a service. For details, see Services Interconnected with Cloud Eye.
Array of objects
Specifies the list of metric dimensions.
For details, see Table 4.
metric_name
String
Specifies the metric ID. For example, if the monitoring metric of an ECS is CPU usage, metric_name is cpu_util. For details, see Services Interconnected with Cloud Eye.
Table 4 dimensions field data structure description Parameter
Type
Description
name
String
Specifies the dimension. For example, the ECS dimension is instance_id. For details about the dimension of each service, see the key column in Services Interconnected with Cloud Eye.
value
String
Specifies the dimension value, for example, an ECS ID.
The value is a string of 1 to 256 characters.
Table 5 alarm_actions field data structure description Parameter
Type
Description
type
String
Specifies the alarm notification type.- notification: indicates that a notification will be sent to the user.
- autoscaling: indicates that a scaling action will be triggered.
notificationList
Array of strings
Specifies the list of objects to be notified if the alarm status changes.
NOTE:The IDs in the list are character strings.
Table 6 ok_actions field data structure description Parameter
Type
Description
type
String
Specifies the notification type when an alarm is triggered.- notification: indicates that a notification will be sent to the user.
- autoscaling: indicates that a scaling action will be triggered.
notificationList
Array of strings
Specifies the list of objects to be notified if the alarm status changes.
NOTE:The IDs in the list are character strings.
Table 7 insufficientdata_actions field data structure description Parameter
Type
Description
type
String
Specifies the notification type when an alarm is cleared. The value is notification.
notificationList
Array of strings
Specifies the list of objects to be notified if the alarm status changes.
NOTE:The IDs in the list are character strings.
Table 8 condition field data structure description Parameter
Type
Description
period
Integer
Specifies the interval (seconds) for checking whether the configured alarm rules are met.
filter
String
Specifies the data rollup method. The following methods are supported:
- average: Cloud Eye calculates the average value of metric data within a rollup period.
- max: Cloud Eye calculates the maximum value of metric data within a rollup period.
- min: Cloud Eye calculates the minimum value of metric data within a rollup period.
- sum: Cloud Eye calculates the sum of metric data within a rollup period.
- variance: Cloud Eye calculates the variance value of metric data within a rollup period.
comparison_operator
String
Specifies the operator of alarm thresholds. Possible values are >, =, <, ≥, and ≤.
value
Double
Specifies the alarm threshold. The value ranges from 0 to Number. MAX_VALUE (1.7976931348623157e+108).
For detailed thresholds, see the value range of each metric in the appendix. For example, you can set ECS cpu_util in Services Interconnected with Cloud Eye to 80.
unit
String
Specifies the data unit. The value contains a maximum of 32 characters.
count
Integer
Specifies the number of consecutive occurrence times that the alarm policy was met. The value ranges from 1 to 5.
suppress_duration
Integer
Specifies the interval for triggering an alarm if the alarm persists.
Possible values are as follows:
0: Cloud Eye triggers the alarm only once.
300: Cloud Eye triggers the alarm every 5 minutes.
600: Cloud Eye triggers the alarm every 10 minutes.
900: Cloud Eye triggers the alarm every 15 minutes.
1800: Cloud Eye triggers the alarm every 30 minutes.
3600: Cloud Eye triggers the alarm every 1 hour.
10800: Cloud Eye triggers the alarm every 3 hours.
21600: Cloud Eye triggers the alarm every 6 hour.
43200: Cloud Eye triggers the alarm every 12 hours.
86400: Cloud Eye triggers the alarm every day.
- Example response
{ "metric_alarms": [ { "alarm_name":"alarm-ipwx", "alarm_description":"", "metric": { "namespace":"SYS.ELB", "dimensions": [ { "name":"lb_instance_id", "value":"44d06d10-bce0-4237-86b9-7b4d1e7d5621" } ], "metric_name":"m8_out_Bps" }, "condition": { "period":300, "filter":"sum", "comparison_operator":">=", "value":0, "unit":"", "count":1 }, "alarm_enabled":true, "alarm_level": 2, "alarm_action_enabled":true, "alarm_actions": [ { "type":"notification", "notificationList":["urn:smn:region:68438a86d98e427e907e0097b7e35d48:sd"] } ], "ok_actions": [ { "type":"notification", "notificationList":["urn:smn:region:68438a86d98e427e907e0097b7e35d48:sd"] } ], "insufficientdata_actions": [ { "type": "notification", "notificationList": [ "urn:smn:region:68438a86d98e427e907e0097b7e35d48:sd" ] } ], "alarm_action_begin_time": "00:00", "alarm_action_end_time": "23:59", "alarm_id":"al1498096535573r8DNy7Gyk", "update_time":1498100100000, "alarm_state":"alarm" } ] }
Returned Values
- Normal
- Abnormal
Returned Value
Description
400 Bad Request
Request error.
401 Unauthorized
The authentication information is not provided or is incorrect.
403 Forbidden
You are forbidden to access the page requested.
408 Request Timeout
The request timed out.
429 Too Many Requests
Concurrent requests are excessive.
500 Internal Server Error
Failed to complete the request because of an internal service error.
503 Service Unavailable
The service is currently unavailable.
Error Code
For details, see Error Codes.
Last Article: Querying the Alarm Rule List
Next Article: Enabling or Disabling an Alarm Rule
Did this article solve your problem?
Thank you for your score!Your feedback would help us improve the website.