ALM-3276800045 Indicates that the board ports conflict with each other 147456
Description
ENTITYTRAP/4/PORTCONFLICT: OID [OID] Some ports on the board and subcard conflict with each other. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")
The switch worked in card interface working mode, but no card was installed.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
3276800045 |
Warning |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Index. |
EntityPhysicalIndex |
Physical index. |
PhysicalName |
Entity name. |
EntityTrapEntType |
Entity type. |
EntityTrapFaultID |
Error code 147456. |
EntityTrapReasonDescr |
Cause of the alarm. |
Impact on the System
The four 10GE SFP+ Ethernet optical interfaces on the front panel could not be used.
Possible Causes
The switch worked in card interface working mode, but no card was installed.
Procedure
Install a card supported by the switch.