ALM-135462942 The optical module is invalid 136202

Description

ENTITYTRAP/3/OPTTEMALM:OID [OID] The temperature of optical exceeds the upper alarm threshold or falls below the lower alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The optical module temperature is below the lower threshold.

Attribute

Alarm ID

Alarm Severity

Alarm Type

135462942

Minor

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Indicates the index.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the name of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntityTrapReasonDescr

Indicates the description of the alarm cause.

Impact on the System

The optical module may fail to work properly, affecting services.

Possible Causes

The ambient temperature is too low.

Procedure

Run the display transceiver slot slot-id verbose command to check whether the temperature of the optical module is within the allowed range.

  • If the temperature of the optical module is within the allowed range, collect alarms, logs, and configurations, and contact technical support personnel.

  • If the temperature of the optical module is out of the allowed range, replace the optical module.