ALM-135462942 The optical module is invalid 136221
Description
ENTITYTRAP/3/OPTMAYINVALID: OID [OID] The optical power exceeds the upper warning threshold or falls below the lower warning threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")
The transmit power of an optical module is too low.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
135462942 |
Minor |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntityTrapReasonDescr |
Indicates the description of the alarm cause. |
Impact on the System
This alarm does not affect system operating if the interface on which the optical module is installed works properly.
Possible Causes
The transmit power of the optical module is too low.
Procedure
- Run the display transceiver slot slot-id verbose command in the system view to check whether the transmit power Tx Power of the optical module is within the allowed range.
- Replace the optical module, and check whether the alarm is cleared.
Related Information
None