ALM-303046698 The card or subcard temperature is too high 143617
Description
SRM_ENTITY/6/ENTITYBRDTEMPALARM:OID 1.3.6.1.4.1.2011.5.25.219.2.10.13 Temperature rise over or fall below the warning alarm threshold. (Index=[integer], EntityPhysicalIndex=[integer], PhysicalName="[STRING]", EntityThresholdType=[integer], EntityThresholdValue=[integer], EntityThresholdCurrent=[integer], EntityTrapFaultID=143617)
The board or subcard temperature was too high.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046698 |
Major |
equipmentAlarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the physical entity index. |
EntPhysicalName |
Indicates the physical entity name. |
EntityType |
Indicates the entity type. |
EntityTrapFaultID |
Indicates the error code. |
Impact on the System
The device may be restarted, causing service interruption.
Possible Causes
Cause 1: The board temperature exceeds the upper alert threshold.
Cause 2: The fan is faulty.
Procedure
- Run the display device command and check whether the fan status restores normal.
- Y =>2
- N =>3
- Lower the ambient temperature, run the display temperature all command, and check whether the board temperature is Normal.
- Y =>4
- N =>3
- Collect the information about alarms, logs, and configurations, and then contact Huawei technical support personnel.
- End.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot