Help Center/ Huawei Qiankun CloudService/ More Documents/ Device Alarm Handling/ V200 LSW Alarms/ ALM-3276800020 Indicates that I2C abnormal 68080
Updated on 2024-01-25 GMT+08:00

ALM-3276800020 Indicates that I2C abnormal 68080

Description

SRM/3/ENTITYINVALID: OID [OID] I2C is abnormal. (EntityPhysicalIndex=[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])

The I2C was faulty.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800020

Minor

Equipment alarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Indicates the index of an entity.

BaseTrapSeverity

Indicates the alarm severity.

BaseTrapProbableCause

Indicates the possible causes of an alarm.

BaseTrapEventType

Indicates the type of an alarm.

EntPhysicalContainedIn

Indicates the index of a parent entity.

EntPhysicalName

Indicates the name of an entity.

RelativeResource

Indicates the entity-related resources.

ReasonDescription

Indicates the reason description of an alarm.

Impact on the System

One or more interfaces do not work normally.

Possible Causes

The I2C has failed.

Procedure

  1. Switch services from the interfaces affected by the I2C failure to interfaces that can work normally. If you still want to use an affected interface, rectify the I2C fault, and then run the clear configuration interface interface-type interface-num command to clear interface configuration and reconfigure the interface.
  2. If the fault cannot be rectified and services cannot be switched to normal interfaces, replace the device.

Related Information

None