ALM-67706900 hwRuAuthFail
Description
The authentication to the remote unit failed. (RemoteUnitEsn=[RemoteUnitEsn])
The central switch fails to authenticate the RU.

This alarm is supported only on S5735-L-V2, S5735-S-V2, S5735I-S-V2, S5735I-L-V2, S6730-H-V2, S5732-H-V2.
Attribute
Alarm ID |
OID |
Alarm Severity |
Alarm Type |
---|---|---|---|
67706900 |
1.3.6.1.4.1.2011.5.25.667.2.37 |
major |
Quality of service alarm |
Parameters
Parameter |
Description |
---|---|
RemoteUnitEsn |
ESN of the RU. |
Impact on the System
Configurations cannot be delivered to the RU, and the RU cannot be restarted.
Possible Causes
The default domain of the central switch is not loaded with the correct device certificate
Procedure
- Load the correct device certificate to the default domain for the central switch. Run the display remote-unit [ connect-interface interface-type interface-number | name remote-unit-name | verbose ] command to check whether the Authen Result field of the RU is Success.
- If so, go to Step 3.
- If not, go to Step 2.
- Collect trap, log, and configuration information, and contact technical support personnel.
- End.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot