Updated on 2024-01-25 GMT+08:00

ALM-67706884 hwRuPortCrcErrorRising

Description

Remote unit CRC error is rising. (RemoteUnitEsn=[RemoteUnitEsn], InterfaceName=[InterfaceName], CrcErrorStatistics=[CrcErrorStatistics], CrcErrorThreshold=[CrcErrorThreshold], CrcErrorInterval=[CrcErrorInterval](s))

The number of interface CRC errors on the remote module exceeded the threshold.

This alarm is supported only on S5735-L-V2, S5735-S-V2, S5735I-S-V2, S5735I-L-V2, S6730-H-V2, S5732-H-V2.

Attribute

Alarm ID

OID

Alarm Severity

Alarm Type

67706884

1.3.6.1.4.1.2011.5.25.667.2.9

Major

Quality of service alarm

Parameters

Parameter

Description

RemoteUnitEsn

ESN of the remote module.

InterfaceName

Port number of the remote module.

CrcErrorStatistics

Statistics in a CRC period.

CrcErrorThreshold

CRC alarm threshold. The value is fixed at 20.

CrcErrorInterval

Alarm period. The value is fixed at 60s.

Impact on the System

Some service data on the port is discarded.

Possible Causes

  • Cause 1: transceiver fault.
  • Cause 2: Fiber failure.

Procedure

  • Cause 1: transceiver fault.
    Replace the optical module and check whether the alarm is cleared.
    • If so, no further action is required.
    • If not, collect alarm and configuration information, and contact technical support.
  • Cause 2: Fiber failure.
    Replace the optical fiber and check whether the alarm is cleared.
    • If so, no further action is required.
    • If not, collect alarm and configuration information, and contact technical support.