ALM-15795049 hwHrpDeviceID

Description

HRP link changes to [hwHrpTrapLinkState]. Local device ID is [hwHrpTrapLocalID], peer device ID is [hwHrpTrapPeerID].

The heartbeat status of the high availability system is abnormal.

Attribute

Alarm ID

OID

Alarm Severity

Alarm Type

15795049

1.3.6.1.4.1.2011.6.122.51.2.2.2

Critical

Quality of service alarm

Parameters

Name Meaning

hwHrpTrapLinkState

Connection status of dual-system hot backup

hwHrpTrapLocalID

MAC address of the management network port on the local device

hwHrpTrapPeerID

MAC address of the management network port on the remote device.

Impact on the System

If both the active and standby devices are in the active state, services are interrupted.

Possible Causes

  • Cause 1: Manually disable dual hot standby function.
  • Cause 2: The link between the heartbeat interfaces of the active and standby devices is interrupted.
  • Cause 3: The master device or the backup device fails to send and receive heartbeat packets.

Procedure

  • Cause 1: Manually disable dual hot standby function.

    Check whether the hot standby configuration on the active and standby devices is correct.

  • Cause 2: The link between the heartbeat interfaces of the active and standby devices is interrupted.

    Run the ping command to check whether the link between the heartbeat interfaces of the active and standby devices is normal.

  • Cause 3: The master device or the backup device fails to send and receive heartbeat packets.

    Check whether the status of the active and standby devices is normal.

Clearing

After the fault is rectified, the system clears this alarm, removing the need to manually clear it. This alarm will not be displayed on the CurrentAlarms page.