Updated on 2025-11-18 GMT+08:00

Software Versions Required by Different Models

You can use elastic BMSs or ECSs as the node resources in the elastic cluster resource pool. The OSs and CCE cluster versions vary depending on the node model. This section describes the software versions required by different models, which helps you create images and upgrade software.

Software Versions Required by BMSs

Table 1 BMS

Type

PU Type

RDMA Network Protocol

OS

Applicable Scope

Dependent Plug-in

NPU

ascend-snt9b

RoCE

  • OS: EulerOS 2.10 64-bit (recommended)
  • Kernel version: 4.19.90-vhulk2211.3.0.h1543.eulerosv2r10.aarch64
  • Architecture type: aarch64
  • Cluster type: CCE Standard
  • Cluster version: v1.23 (v1.23.5-r0 or later), v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs
  • huawei-npu
  • npu-driver
  • volcano

For details about the plug-in version mapping, see Table 4.

RoCE

  • OS: Huawei Cloud EulerOS 2.0 64-bit
  • Kernel version: 5.10.0-60.18.0.50.r865_35.hce2.aarch64
  • Architecture type: aarch64
  • Cluster type: CCE Turbo
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: ENI
  • Cluster forwarding mode: iptables or ipvs

ascend-snt9

RoCE

  • OS: EulerOS 2.8 64-bit
  • Kernel version: 4.19.36-vhulk1907.1.0.h619.eulerosv2r8.aarch64
  • Architecture type: aarch64
  • Cluster type: CCE Standard or Turbo
  • Cluster version: v1.23 (v1.23.5-r0 or later), v1.25, or v1.28 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network, VPC, or ENI
  • Cluster forwarding mode: iptables or ipvs

GPU

gpu-ant8

RoCE

  • OS: EulerOS 2.10 64-bit
  • Kernel version: 4.18.0-147.5.2.15.h1109.eulerosv2r10.x86_64
  • Architecture type: x86
  • Cluster type: CCE Standard or Turbo
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC

    Distributed training only supports container tunnel network.

  • Cluster forwarding mode: iptables or ipvs
  • gpu-beta
  • gpu-driver
  • rdma-sriov-dev-plugin

For details about the plug-in version mapping, see Table 4.

gpu-ant1

RoCE

  • OS: EulerOS 2.10 64-bit
  • 4.18.0-147.5.2.15.h1109.eulerosv2r10.x86_64
  • Architecture type: x86
  • Cluster type: CCE Standard or Turbo
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC

    Distributed training only supports container tunnel network.

  • Cluster forwarding mode: iptables or ipvs

gpu-vnt1

RoCE|IB

  • OS: EulerOS 2.9 64-bit (recommended)
  • Kernel version: 4.18.0-147.5.1.6.h841.eulerosv2r9.x86_64
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC

    Distributed training only supports container tunnel network.

  • Cluster forwarding mode: iptables or ipvs
  • Remote direct memory access (RDMA) is a direct memory access from the memory of one computer into that of another without involving either one's operating system.
  • RDMA over Converged Ethernet (RoCE) is a network protocol which allows RDMA over an Ethernet network.
  • InfiniBand (IB) is a computer networking communications standard used in high-performance computing. It is used for data interconnect both among and within computers.

Software Versions Required by ECSs

Table 2 ECS

Type

PU Type

OS

Applicable Scope

Dependent Plug-in

NPU

ascend-snt3p-300i

  • OS: Huawei Cloud EulerOS 2.0 64-bit
  • Architecture type: x86 or Arm
  • Cluster type: CCE Standard
  • Cluster version: v1.23 (v1.23.5-r0 or later), v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs
  • os-node-agent
  • volcano
  • huawei-npu
  • npu-driver

For details about the plug-in version mapping, see Table 4.

  • OS: EulerOS 2.9
  • Architecture type: x86
  • Cluster type: CCE Standard or Turbo
  • Cluster version: v1.23 (v1.23.5-r0 or later), v1.25, or v1.28 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network, VPC, or ENI
  • Cluster forwarding mode: iptables or ipvs
  • huawei-npu
  • npu-driver
  • volcano

For details about the plug-in version mapping, see Table 4.

ascend-snt3

  • OS: EulerOS 2.5
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23 or v1.25
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs
  • OS: EulerOS 2.8
  • Architecture type: Arm
  • Cluster type: CCE Standard
  • Cluster version: v1.23 or v1.25
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC

    Cluster forwarding mode: iptables or ipvs

ascend-snt9b

  • OS: Huawei Cloud EulerOS 2.0 64-bit
  • Architecture type: Arm
  • Cluster type: CCE Standard
  • Cluster version: v1.23 (v1.23.5-r0 or later), v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs

GPU

gpu-vnt1

  • OS: EulerOS 2.9
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs
  • gpu-beta
  • gpu-driver
  • rdma-sriov-dev-plugin

For details about the plug-in version mapping, see Table 4.

gpu-ant03

  • OS: EulerOS 2.9
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs

gpu-ant1-pcie40

  • OS: EulerOS 2.9
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs

gpu-tnt004

  • OS: EulerOS 2.9
  • Architecture type: x86
  • Cluster type: CCE Standard
  • Cluster version: v1.23, v1.25, v1.28, or v1.31 (recommended)
  • Cluster scale: 50, 200, 1000, or 2000
  • Cluster network mode: container tunnel network or VPC
  • Cluster forwarding mode: iptables or ipvs

Mapping Between Drivers, Plug-in Versions, and CCE Cluster Versions

Table 3 Mapping between driver and CCE cluster versions

Type

Plug-in

Plug-in Version

Matched CCE Cluster Version

Applicable Scope

Plug-in Function

npuDriver

npu-driver

7.5.0.5.220-24.1.0.3 (recommended)

7.1.0.9.220-23.0.6

None

NPU (snt9b)

Upgrades and rolls back NPU drivers.

gpuDriver

gpu-driver

515.65.01 (recommended)

510.47.03

470.182.03

470.57.02

None

GPU

Upgrades and rolls back GPU drivers. The plug-in depends on the gpu-beta version.

Table 4 Mapping between plug-in versions and CCE cluster versions

Plug-in

Plug-in Version

Matched CCE Cluster Version

Applicable Scope

Plug-in Function

gpu-beta

2.8.4 (recommended)

v1.(28|29|30|31|32).*

GPU

Allows containers to use GPU devices.

2.7.63

v1.(28|29|30|31).*

2.7.58

v1.(28|29|30|31).*

huawei-npu

2.1.53 (recommended)

v1.(25|27|28|29|30|31).*

NPU

Allows containers to use Huawei NPU devices.

2.1.47

v1.(21|23|25|27|28|29|30|31).*

volcano

1.18.3 (recommended)

v1.(27|28|29|30|31|32).*

NPU

Kubernetes-based batch processing platform.

1.17.11

v1.(25|27|28|29|30|31|32).*

os-node-agent

7.3.0

None

None

OS plug-in, which is used for fault detection.

icagent

default

The matched CCE version is installed by default.

None

CCE basic component, which is used for logging and monitoring.