Help Center/ MapReduce Service/ User Guide (Ankara Region)/ Alarm Reference/ ALM-45289 PolicySync Heap Memory Usage Exceeds the Threshold
Updated on 2024-11-29 GMT+08:00

ALM-45289 PolicySync Heap Memory Usage Exceeds the Threshold

Alarm Description

The system checks the heap memory usage of the PolicySync service every 60 seconds. This alarm is generated when the heap memory usage of the PolicySync instance exceeds the threshold (95% of the maximum memory) for 10 consecutive times. This alarm is cleared when the heap memory usage is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Alarm Type

Service Type

Auto Cleared

45289

Major

Quality of service

Ranger

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Additional Information

Trigger Condition

Specifies the alarm triggering condition.

Impact on the System

The service may break down. Ranger cannot connect to LakeFormation.

Possible Causes

The heap memory of the PolicySync instance is overused or the heap memory is inappropriately allocated.

Handling Procedure

  1. Log in to FusionInsight Manager and choose O&M > Alarm > Alarms > ALM-45289 PolicySync Heap Memory Usage Exceeds the Threshold. Check the location information of the alarm and view the host name of the instance for which the alarm is generated.
  2. On FusionInsight Manager, choose Cluster > Services > Ranger > Instance. Select the role corresponding to the host name of the instance for which the alarm is generated. Click the drop-down list in the upper right corner of the chart area and choose Customize > CPU and Memory > PolicySync Heap Memory Usage. Click OK.
  3. Check whether the heap memory used by PolicySync reaches the threshold (95% of the maximum heap memory by default).

    • If yes, go to 4.
    • If no, go to 6.

  4. On FusionInsight Manager, choose Cluster > Services > Ranger > Instance > PolicySync. Click Instance Configuration and then All Configurations, and choose PolicySync > System. Set -Xmx in the GC_OPTS parameter to a larger value based on site requirements and save the configuration.

    If this alarm is generated, the heap memory configured for PolicySync cannot meet the heap memory required by the PolicySync process. You are advised to change the value of -Xmx in GC_OPTS to twice that of the heap memory used by PolicySync. You can change the value based on the actual service scenario. Refer to 2 to view the PolicySync heap memory usage.

  5. Restart the affected services or instances and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select Ranger for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M engineers and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.