ALM-12078 Password of User omm Expired
Alarm Description
The system starts at 00:00 every day to check whether the password of user omm has expired every 8 hours. This alarm is generated if the password has expired.
This alarm is cleared when the expiration time of user omm password is changed and the user password status becomes normal.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
12078 |
Critical |
Security |
FusionInsight Manager |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
|
Additional Information |
Detail |
Specifies the details for which the alarm is generated. |
Impact on the System
The password of user omm has expired. The node trust relationship is unavailable, and FusionInsight Manager cannot manage the services. The crontab scheduled task cannot be executed, affecting the ClickHouse service.
Possible Causes
The password of user omm has expired.
Handling Procedure
Check whether the password of user omm in the system has expired.
- Log in to the faulty node as user root.
Run the chage -l ommcommand to view the information about the password of user omm.
- View the value of Password expires to check whether the user configurations have expired.
If the parameter value is never, the user configurations never expire.
- Run the chage -M 'days' omm command to set the validity period of the password for user omm. Eight hours later, check whether the alarm is automatically cleared.
If days is set to 99999, it indicates that the password never expires.
- If it is, no further action is required.
- If it is not, go to 4.
Collect fault information.
- On FusionInsight Manager, choose O&M> Log > Download.
- Select NodeAgent for Service and click OK.
- Click edit icon in the upper right corner. In the displayed dialog box, set Start Date and End Date to 10 minutes before and after the alarm generation time respectively and click OK. Then, click Download.
- Contact the O&M engineers and send the collected log information.