Enabling Break Protection to Protect Origin Servers
If there are too many 502 Bad Gateway, 504 Gateway Timeout, or delayed responses after your website is connected to WAF, WAF enables break protection to protect your website. The cloud CNAME access is a hosted mode. The default configuration cannot be changed. In dedicated mode, all parameters can be customized, which is the core capability for high service availability and fault self-healing.
Principles
- Breakdown Protection: detects abnormal response codes. If your website experiences excessive 502 Bad Gateway or 504 Gateway Timeout errors after being connected to WAF, WAF breakdown protection will stop forwarding user requests. This protects your website from potential further damage.
- Connection Protection: detects TCP connection delay. If your website experiences excessive request processing delays after being connected to WAF, WAF connection protection will stop forwarding user requests. This protects your website from potential further damage.
- Cloud CNAME access: This function is enabled by default and cannot be disabled. The default value is shown in Table 1 and cannot be changed.
- Dedicated mode: You can enable or disable this function and configure the interruption threshold and protection time based on your service requirements. For details, see Procedure.
| Function | Trigger Condition | Default Value |
|---|---|---|
| Breakdown Protection | When the number of 502/504 errors reaches the 502/504 Error Threshold (the number of 502/504 errors returned every 30 seconds) and the percentage of 502/504 errors reaches the 502/504 Error Percentage (%) (the percentage of 502/504 errors in the total number of requests), WAF automatically triggers the breakdown protection for the website within the Initial Downtime (s). WAF then stops forwarding user requests to relieve the access pressure caused by a large number of 502/504 errors. If the breakdown protection is triggered continuously within one hour, WAF prolongs the downtime protection time based on the configured Multiplier for Consecutive Breakdowns. For example, assume that you set the initial downtime to 180s and the maximum multiplier to 3. If breakdown protection is triggered a second time, the website downtime is 360s (180s x 2). If the breakdown protection is triggered a third or fourth time, the website downtime is 540s (180s x 3). The breakdowns are counted from 0 when the total breakdown duration exceeds one hour. |
|
| Connection Protection | When the number of requests waiting for responses reaches the value of Pending URL Request Threshold, WAF automatically triggers the connection protection and protects the website within the period specified by Duration (s). WAF stops forwarding user requests during this period to relieve the pressure caused by a large number of requests. |
|
Typical Application Scenarios (Dedicated Mode)
| Scenario | Scenario | Solution |
|---|---|---|
| Static official websites, such as government and enterprise website portals | Low concurrency and high stability |
|
| Promotion sales on e-commerce platforms | High concurrency, large traffic fluctuation, and fear of false breakdown protection |
|
| Microservice/Backend API service | API failure and connection timeout |
|
| Small games/Live streaming services with heavy traffic | An excessive number of persistent connections that are likely to cause a queuing backlog |
|
Constraints
| Function | Constraint |
|---|---|
| Mode |
|
| Region constraints | You can check the console to see whether this function is supported in a specific region. |
Prerequisites
- You have added your website to WAF. For details, see Access Management.
- You have upgraded the dedicated WAF instance to the latest version. For details, see Upgrading a Dedicated WAF Instance.
Configuring Break Protection
You can configure break protection by referring to Procedure, Configuration Suggestions and Verification Methods.
Procedure
- Log in to the WAF console.
- Click
in the upper left corner and select a region or project. - (Optional) If you have enabled the enterprise project function, in the upper part of the navigation pane on the left, select your enterprise project from the Filter by enterprise project drop-down list. Then, WAF will display the related security data in the enterprise project on the page.
- In the navigation pane on the left, choose .
- On the Protected Objects page, click the target domain name.
- In the Break Protection area, click the status icon
to toggle it on. - Click
next to each parameter, edit Breakdown Protection and Connection Protection parameters to meet your requirements, and click OK to save settings. Table 2 describes these parameters. Table 2 Parameter description Parameter
Description
Example Value
Breakdown Protection
502/504 Error Threshold
30s 502/504 Error Threshold
1,000
502/504 Error Percentage (%)
A breakdown is triggered when the 502/504 error threshold and percentage threshold have been reached.
90
Initial Downtime (s)
Protection period upon the first breakdown. During this period, WAF stops forwarding client requests.
180
Multiplier for Consecutive Breakdowns
The maximum multiplier you can use for consecutive breakdowns. The number of breakdowns is counted from 0 every time the accumulated breakdown protection duration reaches 3,600s.
For example, assume that Initial Downtime (s) is set to 180s and Multiplier for Consecutive Breakdowns is set to 3.- If the breakdown is triggered for the second time, that is, less than 3, the protection duration is 360s (180s x 2).
- If the breakdown is triggered for the third or fourth time, that is, greater than or equal to 3, the protection duration is 540s (180s x 3).
- The breakdowns are counted from 0 when the total downtime duration exceeds one hour (3,600s).
3
Connection Protection
Pending URL Request Threshold
Connection Protection is triggered when the number of read URL requests reaches the threshold you configure.
6,000
Duration (s)
Protection duration. During this period, WAF stops forwarding client requests.
60
Configuration Suggestions
- Do not set the thresholds too low. If the thresholds are too low, normal traffic fluctuations may trigger a breakdown protection, resulting in service unavailability.
- Do not set the coefficient too high. It is recommended that the coefficient be between 1.5 and 2. If the coefficient is too high, traffic will still be blocked for a long time after the fault is rectified.
- The initial protection duration should not be too long. For common services, it should be between 10s and 20s. If the duration is too long, user retry access will be affected.
- The two thresholds must be set together. If only the quantity is considered and the proportion is ignored, or vice versa, misjudgment is likely to occur or the protection may not be triggered.
Verification Methods
- Breakdown Protection: When the number of 502/504 errors returned by the protected website exceeds 1,000 and accounts for 90% or more of the total access requests of the website for the first time, the first breakdown protection is triggered. During the first breakdown protection, WAF stops forwarding client requests for 180s (that is, blocks visitors' access to the website for 180s). If a second consecutive breakdown protection is triggered, WAF stops forwarding client requests for 360s (180 x 2). If a third or more consecutive breakdowns are triggered, WAF stops forwarding client requests for 540s (180s x 3). The breakdowns are counted from 0 when the total downtime duration exceeds one hour (3,600s).
- Connection Protection: When the number of read URL requests in the waiting queue exceeds 6,000, WAF stops forwarding client requests for 60s and returns the maintenance page of the website to visitors.
What is your overall rating for this page?
Thank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot