ALM-45657 FlinkServer SQL Gateway Unavailable
This section applies to MRS 3.6.0-LTS.1 or later.
Alarm Description
The alarm module checks the FlinkServer SQL Gateway status every 60 seconds. This alarm is generated when the SQL Gateway cannot be connected. This alarm is cleared when the SQL Gateway recovers.
Alarm Attributes
| Alarm ID | Alarm Severity | Alarm Type | Service Type | Auto Cleared |
|---|---|---|---|---|
| 45657 | Major | Environment | Flink | Yes |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Source | Specifies the cluster for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. | |
| RoleName | Specifies the role for which the alarm was generated. |
Impact on the System
When the FlinkServer SQL Gateway is unavailable, the syntax verification, lineage analysis, and catalog management functions on the FlinkServer page are also unavailable.
Possible Causes
The SQL Gateway port binding failed, and the SQL Gateway becomes unavailable.
Handling Procedure
View alarm information.
- Log in to MRS Manager as a user with FlinkServer administrator permissions.
- Choose O&M > Alarm > Alarms > ALM-45657 FlinkServer SQL Gateway Unavailable, and view the host name in the Location field. Click the hyperlink next to HostName, and check and record the IP address corresponding to the host name.
Check whether the SQL Gateway port failed to bind.
- Log in to the host for which the alarm is reported as user omm.
- Run the following command to check whether the port is occupied by another process:
netstat -anp | grep 28947
- Wait for 5 minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to Step 6.
Collect fault information.
- On MRS Manager, choose O&M > Log > Download.
- Expand the Service drop-down list, and select Flink for the target cluster.
- Click
in the upper right corner, and select a time span starting 30 minutes before and ending 30 minutes after when the alarm was generated. Then, click Download to collect the logs. - Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None