ALM-45643 MemTable Size of RocksDB Continuously Exceeds the Threshold
This section applies to MRS 3.3.0 or later.
Alarm Description
The system checks the RocksDB monitoring data of jobs at the user-specified alarm reporting interval (metrics.reporter.alarm.job.alarm.rocksdb.metrics.duration, 180s by default). This alarm is generated when the MemTable size of RocksDB for a job continuously exceeds the threshold (metrics.reporter.alarm.job.alarm.rocksdb.get.micros.threshold, 50000 microseconds by default). This alarm is cleared when the MemTable size of RocksDB for the job is less than or equal to the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45643 |
Minor |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
ApplicationName |
Specifies the name of the application for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
JobName |
Specifies the job for which the alarm is generated. |
Impact on the System
The checkpoint performance of Flink jobs is affected. There is no impact on the FlinkServer.
Possible Causes
The write pressure of RocksDB is high.
Handling Procedure
Check TaskManager logs for the write pressure of RocksDB and collect logs.
- Log in to FusionInsight Manager as a user who has the FlinkServer management permission.
- Choose O&M > Alarm > Alarms > ALM-45643 MemTable Size of RocksDB Continuously Exceeds the Threshold, view Location, and obtain the name of the task for which the alarm is generated.
- Choose Cluster > Services > Yarn and click the link next to ResourceManager WebUI to go to the native Yarn page.
- Locate the abnormal task based on its name displayed in Location, search for and record the application ID of the job, and check whether the job logs are available on the Yarn page.
Figure 1 Application ID of a job
- Click the application ID of the failed job to go to the job page.
- Click Logs in the Logs column to view JobManager logs.
Figure 2 Clicking Logs
- Click the ID in the Attempt ID column and click Logs in the Logs column to view and save TaskManager logs. Then go to 7.
Figure 3 Clicking the ID in the Attempt ID column
Figure 4 Clicking Logs
You can also log in to Manager as a user who has the management permission for the current Flink job. Choose Cluster > Services > Flink, and click the link next to Flink WebUI. On the displayed Flink web UI, click Job Management, click More in the Operation column, and select Job Monitoring to view TaskManager logs.
- Click Logs in the Logs column to view JobManager logs.
If logs are unavailable on the Yarn page, download logs from HDFS.
- On Manager, choose Cluster > Services > HDFS, click the link next to NameNode WebUI to go to the HDFS page, choose Utilities > Browse the file system, and download logs in the /tmp/logs/Username/bucket-logs-tfile/Last four digits of the task application ID/Application ID of the task directory.
Check whether the write pressure of RocksDB is high.
- Check whether the value of rocksdb.size-all-mem-tables (unit: byte) in the TaskManager monitoring logs (keyword RocksDBMetricPrint) is greater than or equal to the total write buffer size (Total write buffer = write_buffer_size x max_write_buffer_number).
- If yes, adjust the values of the following custom parameters on the job development page of the Flink web UI, save the settings, and go to 8.
Table 1 Custom parameters Parameter
Default Value
Description
state.backend.rocksdb.writebuffer.count
- 2
- 4: enables SPINNING_DISK_OPTIMIZED_HIGH_MEM.
- Number of buffers
- 2 to 10 are recommended. Adjust the value based on service requirements.
state.backend.rocksdb.writebuffer.size
64MB
- Buffer size
- 64MB to 256MB are recommended.
state.backend.rocksdb.thread.num
- 2
- 4: enables SPINNING_DISK_OPTIMIZED_HIGH_MEM.
- Number of flush threads. Increase the number of threads to quickly flush memory data to disks.
- When the number of threads is increased, the number of vCores also needs to be increased.
- 2 to 10 are recommended.
- If no, go to 9.
- If yes, adjust the values of the following custom parameters on the job development page of the Flink web UI, save the settings, and go to 8.
- Restart the job and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 9.
- Contact O&M personnel and send the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot