ALM-45454 ClickHouse Has Tables with Too Frequent Data Writes
Alarm Description
The system checks whether ClickHouse nodes have tables with high write frequency within the previous day every day. This alarm is generated when the system detects such tables. You can view and adjust the write frequency threshold by setting the MAX_INSERT_NUMBER_PER_SECOND parameter of the ClickHouse service.
This alarm is automatically cleared when the system detects that there is no table with high write frequency on ClickHouse nodes on the previous day.
This section applies only to MRS 3.5.1-LTS or later.
Alarm Attributes
| Alarm ID | Alarm Severity | Auto Cleared |
|---|---|---|
| 45454 | Major | Yes |
Alarm Parameters
| Type | Parameter | Description |
|---|---|---|
| Location Information | Source | Specifies the cluster or system for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. | |
| RoleName | Specifies the role for which the alarm was generated. | |
| HostName | Specifies the host for which the alarm was generated. |
Impact on the System
If data is written into tables too frequently, the system may become overloaded and the write operations may even fail.
Possible Causes
Batch write is not implemented for the service.
Handling Procedure
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
- Log in to the node where the client is installed as the client installation user and run the following commands:
cd {Client installation path}
source bigdata_env
- For a cluster with Kerberos authentication enabled (security mode):
clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --port 9440 --secure
- For a cluster with Kerberos authentication disabled (normal mode):
clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --user Username --password --port 9440
- For a cluster with Kerberos authentication enabled (security mode):
- Run the following statement to query the tables with high write frequency:
select tables, cnt from (with toStartOfInterval(event_time,toIntervalSecond(600)) As time_ SELECT time_ , tables, count() as cnt FROM system.query_log WHERE type='QueryFinish' and query_kind = 'Insert' and event_date = '${alarm_date}' GROUP BY time_, tables) where cnt >= (${MAX_INSERT_NUMBER_PER_SECOND} * 600);
- alarm_date: the day before the alarm is generated. For example, if the alarm is generated on February 20, 2025, the value is 2025-02-19.
- MAX_INSERT_NUMBER_PER_SECOND: write frequency threshold. To obtain the threshold, log in to FusionInsight Manager and choose Cluster > Services > ClickHouse > Configurations > All Configurations.
- Optimize the service logic based on the results obtained in Step 3.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select ClickHouse for the target cluster.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.