Updated on 2026-09-24 GMT+08:00

ALM-45453 Keeper Disconnected

This section applies only to MRS 3.6.0 and later versions.

Alarm Description

The system checks the connection between ClickHouse and Keeper every minute. This alarm is generated when the system detects that the connection fails due to a connection exception or the connection fails for three consecutive times due to Keeper disconnection.

This alarm is automatically cleared when the system detects that the connection is normal.

This section applies only to MRS 3.6.0-LTS or later.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

45453

Critical

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster or system for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

RoleName

Specifies the role for which the alarm was generated.

HostName

Specifies the host for which the alarm was generated.

Impact on the System

If ClickHouse is disconnected from Keeper, the ClickHouse service cannot be used.

Possible Causes

  • Keeper is abnormal.
  • The ClickHouse service is overloaded.

Handling Procedure

Check whether ClickHouseKeeper is normal.

  1. On FusionInsight Manager, choose Cluster > Services > ClickHouse > ClickHouseKeeper.
  2. Check whether ClickHouseKeeper instances are normal.

  3. Select the instances whose status is not Normal, click More, and select Restart Instance.
  4. Check whether the instance status becomes normal after the restart.

  5. Choose O&M > Alarm > Alarms and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

Check whether the ClickHouse service is overloaded.

  1. Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
  2. Log in to the node where the client is installed as the client installation user and run the following commands:

    cd {Client installation path}

    source bigdata_env

    • For a cluster with Kerberos authentication enabled (security mode):

      kinit Component service user

      clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --port 9440 --secure

    • For a cluster with Kerberos authentication disabled (normal mode):

      clickhouse client --host IP address of the ClickHouseServer instance for which the alarm is reported --user Username --password --port 9440

  3. Check whether data is frequently written to the system table. If yes, wait until the service execution is complete and check whether the alarm is cleared.

    SELECT query_id, user, FQDN(), elapsed, query FROM system.processes ORDER BY query_id;

    • If yes, no further action is required.
    • If no, go to Step 9.

  4. Check whether a large amount of data is written. If yes, wait until the task is complete and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 10.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select ClickHouse for the target cluster.
  3. Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
  4. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
  5. Contact O&M engineers and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information