ALM-19035 Size of the RegionServer Call Queue Exceeds the Threshold
Alarm Description
The system checks the size of the RegionServer call queue for each HBase service every 30 seconds. This alarm is generated when the call queue of a RegionServer instance is bigger than the threshold for 10 consecutive times.
This alarm is cleared when the call queue of a RegionServer instance is no bigger than the threshold.
This alarm applies only to MRS 3.3.1 or later.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
19035 |
|
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
|
Additional Information |
Threshold |
Specifies the threshold for generating the alarm. |
Impact on the System
Request queues are stacked, and the RegionServer memory GC pressure increases. As a result, the response time of read requests increases. For latency-sensitive services, a large number of service read requests may time out.
Possible Causes
- The RegionServer heap memory configuration is improper.
- A slow disk fault occurred.
- The RegionServer configuration is improper.
- Regions of RegionServers are not evenly distributed and hotspotting occurred.
- The latency of WAL Sync operations is high.
Handling Procedure
- Log in to FusionInsight Manager and choose O&M. In the navigation pane on the left, choose Alarm > Alarms. On the page that is displayed, locate the row containing the alarm whose Alarm ID is 19035, and view the service instance and host name in Location.
Check the heap memory configuration.
- In the alarm list on FusionInsight Manager, check whether the "Heap Memory Usage of the HBase Process Exceeds the Threshold" alarm is generated for the service instance in 1.
- Rectify the fault by following the handling procedure of "ALM-19008 Heap Memory Usage of the HBase Process Exceeds the Threshold".
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 5.
- On FusionInsight Manager, choose Cluster > Services > HBase > Chart, select GC from the chart category, and check whether the GC times and GC monitoring period are normal.
- Click Configurations, search for GC_OPTS, and increase the value of Xmx of the RegionServer within the allowed memory range. Set the value to a number less than or equal to 31 GB. Click Save.
- Click Dashboard and click More > Restart Service to restart the HBase service.
During HBase service restart, the service is unavailable. For example, data cannot be read or written, table operations cannot be performed, and the HBase web UI is inaccessible.
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 9.
Check for slow disk fault.
- Check whether alarm Slow Disk Fault or Disk Unavailable are generated for the same node in 1.
- Rectify the fault by following the handling procedure of "ALM-12033 Slow Disk Fault" or "ALM-12063 Disk Unavailable".
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 12.
Check the RegionServer configuration.
- On FusionInsight Manager, choose Cluster > Service > HBase, click Configurations > All Configurations, and check whether the values of hbase.wal.hsync and hbase.hfile.hsync are true.
- Set both hbase.wal.hsync and hbase.hfile.hsync to false and click Save. Click Dashboard and click More > Restart Service to restart the HBase service.
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 15.
Check whether RegionServer regions are evenly distributed.
- On FusionInsight Manager, choose Cluster > Services > HBase. Click HMaster(Active) on the right of HMaster Web UI to go to the web UI of the HBase instance. View the Base Stats tab in the Region Servers area. Check whether the number of regions in the Num.Regions column is even.
- Log in to the faulty RegionServer node as user omm.
- Run the following commands to go to the client installation directory and set the environment variable:
cd Client installation directory
source bigdata_env
kinit supergroup user group or a user with the Global Admin permission (If Kerberos authentication is disabled for the cluster, skip this operation.)
- Run the following commands to enable load balancing and check whether the function is successfully enabled:
hbase shell
balance_switch true
balancer_enabled
If the command output is true, load balancing is enabled.
Run the balancer command to manually trigger the load balancing function.You are advised to enable and manually trigger the load balancing function during off-peak hours.
- Wait several minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 20.
Check the WAL sync latency.
- On FusionInsight Manager, choose Cluster > Services > HBase > Chart. In the Chart Category area, select Operations. Check whether the value of "P99.9th Percentile of WAL Sync Operation Delay-All Instances" exceeds 500 ms.
- Click Instances, select the RegionServer instance for which the alarm is generated, and choose More > Restart Instance. You also need to perform 22 and provide the logs to O&M engineers for fault locating.
During RegionServer restart, client requests will be retried for multiple times. Read and write operations are affected for a short period of time.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select HBase for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot