ALM-16007 Hive GC Time Exceeds the Threshold
Alarm Description
The system checks the garbage collection (GC) time of the Hive service every 60 seconds. This alarm is generated when the detected GC time exceeds the threshold (exceeds 12 seconds for three consecutive checks.) To change the threshold, choose O&M > Alarm > Thresholds > Name of the desired cluster > Hive. This alarm is cleared when the Hive GC time is shorter than or equal to the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
16007 |
Major |
Quality of service |
Hive |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service name for which the alarm is generated. |
|
RoleName |
Specifies the role name for which the alarm is generated. |
|
HostName |
Specifies the object (host ID) for which the alarm is generated. |
|
Additional Information |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
If the GC time exceeds the threshold, Hive data read and write are affected, task execution may slow down, or services may restart unexpectedly.
Possible Causes
The memory of Hive instances is overused, the heap memory is inappropriately allocated. As a result, GCs occur frequently.
Handling Procedure
Check the GC time.
- On the FusionInsight Manager portal, click O&M > Alarm > Alarms and select the alarm whose Alarm ID is 16007. Then check the role name in Location and confirm the IP adress of the instance.
- On the FusionInsight Manager portal, choose Cluster >Name of the desired cluster > Services > Hive > Instance and click the HiveServer for which the alarm is generated to go to the Dashboard page. Click the drop-down menu in the Chart area and choose Customize > GC, and select Garbage Collection (GC) Time of HiveServer and click OK to check whether the GC time is longer than 12 seconds.
- On the FusionInsight Manager portal, choose Cluster >Name of the desired cluster > Services > Hive > Instance and click the MetaStore for which the alarm is generated to go to the Dashboard page. Click the drop-down menu in the Chart area and choose Customize > GC, and select Garbage Collection (GC) Time of MetaStore and click OK to check whether the GC time is longer than 12 seconds.
Check the current JVM configuration.
- On the FusionInsight Manager portal, choose Cluster >Name of the desired cluster > Services > Hive > Configurations > All Configurations. Choose HiveServer/MetaStore > JVM. Adjust the value of -Xmx in HIVE_GC_OPTS/METASTORE_GC_OPTS as the following rules. Click Save.
Suggestions for GC parameter settings for the HiveServer:
- When the Hive GC time exceeds the threshold, change the value of -Xmx to twice the default value. For example, if -Xmx is set to 2 GB by default, change the value of -Xmx to 4 GB.
- You are advised to change the value of -Xms to set the ratio of -Xms and -Xmx to 1:2 to avoid performance problems when JVM dynamically.
Suggestions for GC parameter settings for the MetaServer:- When the Meta GC time exceeds the threshold, change the value of -Xmx to twice the default value. For example, if -Xmx is set to 2 GB by default, change the value of -Xmx to 4 GB.
- You are advised to change the value of -Xms to set the ratio of -Xms and -Xmx to 1:2 to avoid performance problems when JVM dynamically.
- Click More > Restart Service to restart the service.
- Check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 7.
Collect fault information.
- On the FusionInsight Manager portal of active and standby clusters, choose O&M > Log > Download.
- In the Service, select Hive in the required cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact the O&M engineers and send the collected logs.
Alarm Clearance
After the fault is rectified, the system automatically clears this alarm.
Related Information
None.