Updated on 2022-02-22 GMT+08:00

Lifecycle

The lifecycle of a BMS contains all states from its creation to deletion.

Figure 1 BMS states
Table 1 Description of BMS states

State

Attribute

Description

API Status

Creating

Intermediate state

A BMS is in this state after you request for the BMS and before it enters the running state.

If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.

BUILD/BUILDING

Starting

Intermediate state

It is an intermediate state between Stopped and Running.

If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.

SHUTOFF

Running

Stable state

A BMS is in this state when it is running properly.

A BMS in this state can be used normally.

ACTIVE

Stopping

Intermediate state

It is an intermediate state between Running and Stopped.

If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.

ACTIVE

Stopped

Stable state

A BMS is in this state after it is stopped successfully.

A BMS in this state cannot be used.

SHUTOFF

Restarting

Intermediate state

A BMS is in this state when it is being restarted.

If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.

REBOOT

Forcibly restarting

Intermediate state

A BMS is in this state when it is being forcibly restarted.

HARD_REBOOT

Deleting

Intermediate state

A BMS is in this state when it is being deleted.

If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.

ACTIVE/SHUTOFF/REBOOT/HARD_REBOOT/ERROR

Deleted

Intermediate state

A BMS is in this state after it is deleted successfully. A BMS in this state cannot be used and will be removed from the system in a short time.

DELETED

Faulty

Stable state

A BMS is in this state when an exception occurs on it.

A BMS in this state cannot be used. Contact the administrator to rectify the fault.

ERROR

Rebuilding

Intermediate state

A BMS is in this state when it is being rebuilt.

SHUTOFF

Reinstalling OS

Intermediate state

A BMS is in this state when its OS is being reinstalled.

SHUTOFF

Reinstalling OS failed

Stable state

An exception occurred when the BMS OS was being reinstalled and the reinstallation failed.

A BMS in this state cannot be used. Contact the administrator to rectify the fault.

SHUTOFF