ALM-16000 Percentage of Sessions Connected to the HiveServer to Maximum Number Allowed Exceeds the Threshold
Alarm Description
The system detects the percentage of sessions connected to the HiveServer to the maximum number of allowed sessions every 30 seconds. This indicator can be viewed on the Cluster > Name of the desired cluster > Services > Hive > Instance > HiveServer instance. This alarm is generated when the percentage exceeds the default value.
To change the threshold, choose O&M > Alarm > Thresholds > Name of the desired cluster > Hive > Percentage of Sessions Connected to the HiveServer to Maximum Number of Sessions Allowed by the HiveServer.
When the Trigger Count is 1, this alarm is cleared when the percentage is less than or equal to the threshold. When the Trigger Count is greater than 1, this alarm is cleared when the percentage is less than or equal to the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
16000 |
Versions earlier than MRS 3.3.0: minor (default threshold: 90%) MRS 3.3.0 and later versions: Critical (default threshold: 90%) Major (default threshold: 80%) |
Quality of service |
Hive |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
|
Additional Information |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
If a connection number alarm is generated, the number of sessions connected to HiveServer is too large. As a result, new connections cannot be established, new tasks fail, or even services restart unexpectedly.
Possible Causes
Too many clients are connected to HiveServer.
Handling Procedure
Increase the maximum number of connections to Hive.
- On the FusionInsight Manager portal, Choose Cluster > Name of the desired cluster > Services > Hive > Configurations >All Configurations.
- Search for hive.server.session.control.maxconnections and increase the value of this parameter. If the value of this parameter is A, the threshold is B, and the number of sessions connected to the HiveServer is C, adjust the value of this parameter according to A x B > C. To view the number of sessions connected to the HiveServer, check the value of Statistics for Sessions of the HiveServer on the Hive monitoring page.
- Check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 4.
Collect fault information.
- On the FusionInsight Manager portal, choose O&M > Log > Download.
- Select Hive in the required cluster from the Service.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact the O&M engineers and send the collected logs.
Alarm Clearance
After the fault is rectified, the system automatically clears this alarm.