DataGen
Function
DataGen is used to generate random data for debugging and testing.
Type |
Description |
---|---|
Supported Table Types |
Source table |
Caveats
- When you create a DataGen table, the table field type cannot be Array, Map, or Row. You can use COMPUTED COLUMN in CREATE TABLE to construct similar functions.
- When you create a Flink OpenSource SQL job, set Flink Version to 1.15 in the Running Parameters tab. Select Save Job Log, and specify the OBS bucket for saving job logs.
- Storing authentication credentials such as usernames and passwords in code or plaintext poses significant security risks. It is recommended using DEW to manage credentials instead. Storing encrypted credentials in configuration files or environment variables and decrypting them when needed ensures security. For details, see Flink OpenSource SQL Jobs Using DEW to Manage Access Credentials.
Syntax
create table dataGenSource( attr_name attr_type (',' attr_name attr_type)* (',' WATERMARK FOR rowtime_column_name AS watermark-strategy_expression) ) with ( 'connector' = 'datagen' );
Parameter Description
Parameter |
Mandatory |
Default Value |
Data Type |
Description |
---|---|---|---|---|
connector |
Yes |
None |
String |
Connector to be used. Set this parameter to datagen. |
rows-per-second |
No |
10000 |
Long |
Rows per second to control the emit rate. |
number-of-rows |
No |
None |
Long |
The total number of rows to emit. By default, the total number of rows of generated data is not limited. If the generator type is a sequence generator, data generation will stop when either the maximum number of rows has been reached or the sequence number has reached its end value. |
fields.#.kind |
No |
random |
String |
Generator of the # field. The # field must be an actual field in the DataGen table. Replace # with the corresponding field name. The meanings of the # field for other parameters are the same. The value can be sequence or random.
|
fields.#.min |
No |
Minimum value of the field type specified by # |
Field type specified by # |
This parameter is valid only when fields.#.kind is set to random. Minimum value of the random generator. It applies only to numeric field types specified by #. |
fields.#.max |
No |
Maximum value of the field type specified by # |
Field type specified by # |
This parameter is valid only when fields.#.kind is set to random. Maximum value of the random number. It applies only to numeric field types specified by #. |
fields.#.max-past |
No |
0 |
Duration |
This parameter is valid only when fields.#.kind is set to random. The random generator generates a maximum offset from the current time towards the past. The # specified field is only applicable to timestamp types. |
fields.#.length |
No |
100 |
Integer |
This parameter is valid only when fields.#.kind is set to random. Length of the characters generated by the random generator. It applies only to char, varchar, and string types specified by #. |
fields.#.start |
No |
None |
Field type specified by # |
This parameter is valid only when fields.#.kind is set to sequence. Start value of a sequence generator. |
fields.#.end |
No |
None |
Field type specified by # |
This parameter is valid only when fields.#.kind is set to sequence. End value of a sequence generator. |
Example
Create a Flink OpenSource SQL job. Run the following script to generate random data through the DataGen table and output the data to the Print result table.
create table dataGenSource( user_id string, amount int ) with ( 'connector' = 'datagen', 'rows-per-second' = '1', --Generates a piece of data per second. 'fields.user_id.kind' = 'random', --Specifies a random generator for the user_id field. 'fields.user_id.length' = '3' --Limits the length of the user_id field to 3. 'fields.amount.kind' = 'sequence', --Specify a sequence generator for the amount field. 'fields.amount.start' = '1', --Start value of the amount field 'fields.amount.end' = '1000' --End value of the amount field ); create table printSink( user_id string, amount int ) with ( 'connector' = 'print' ); insert into printSink select * from dataGenSource;
After the job is submitted, the job status changes to Running. You can perform the following operations of either method to view the output result:
- Method 1:
- Log in to the DLI console. In the navigation pane, choose Job Management > Flink Jobs.
- Locate the row that contains the target Flink job, and choose More > FlinkUI in the Operation column.
- On the Flink UI, choose Task Managers, click the task name, and select Stdout to view job logs.
- Method 2: If you select Save Job Log on the Running Parameters tab before submitting the job, perform the following operations:
- Log in to the DLI console. In the navigation pane, choose Job Management > Flink Jobs.
- Click the name of the corresponding Flink job, choose Run Log, click OBS Bucket, and locate the folder of the log you want to view according to the date.
- Go to the folder of the date, find the folder whose name contains taskmanager, download the file whose name contains taskmanager.out, and view result logs.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot