What Do I Do If "over max user connections" Is Displayed When Hue Connects to HiveServer?
Applicable versions: MRS 3.1.0 and earlier
- Modify the following configuration files on all Hue nodes:
/opt/Bigdata/FusionInsight_Porter_8.*/install/FusionInsight-Hue-*/hue/apps/beeswax/src/beeswax/models.py
- Change the configurations in lines 396 and 404.
q = self.filter(owner=user, application=application).exclude(guid='').exclude(secret='')
Modify the content as follows:
q = self.filter(owner=user, application=application).exclude(guid=None).exclude(secret=None)
Figure 1 Modifying the Hue configuration file
Parent topic: Component Configurations