ALM-45741 Guardian Failed to Call the ECS securitykey API
This section applies only to MRS 3.3.0 or later.
Alarm Description
Guardian caches the temporary AK/SK of the ECS agency. When the cache does not exist or is about to expire, Guardian calls the securitykey API of ECS to update the AK/SK. This alarm is generated when calling to the API fails.
Alarm Attributes
Alarm ID |
Alarm Severity |
Alarm Type |
Service Type |
Auto Cleared |
---|---|---|---|---|
45741 |
Major |
Quality of service |
Guardian |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
Impact on the System
The task may fail to obtain the temporary AK/SK for accessing OBS. As a result, OBS cannot be accessed.
Possible Causes
- No ECS agency is bound to the cluster.
- An underlying interface of ECS is abnormal.
Handling Procedure
Check whether an agency is bound to the cluster.
- Log in to the MRS management console.
- In the navigation pane on the left, choose Clusters > Active Clusters. On the page that is displayed, click the cluster name to go to its overview page. Then, check whether the cluster is bound to an agency in the O&M management area.
- Click Manage Agency. On the page that is displayed, rebind the cluster to an agency. Then check whether the alarm is cleared a few minutes later.
- If yes, no further action is required.
- If no, go to 4.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Guardian for the destination cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.