ALM-303046657 The fan module is removed 137216
Description
ENTITYTRAP/4/FANREMOVE: OID [OID] Fan has been removed. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])
The fan is not installed properly.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
303046657 |
Warning |
Equipment alarm |
Parameters
Name |
Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Impact on the System
The temperature of the device will increase due to deterioration of heat dissipation performance. Services are not affected in a short time, but the fault should be rectified quickly.
Possible Causes
The fan was removed or not installed properly.
Procedure
- Check whether the fan was manually removed for routine maintenance.
- If so, the alarm handling ends.
- If not, go to step 2.
- Run the display device command to check whether the fan is registered successfully.
- If so, collect alarm information and configuration information, and then contact technical support personnel.
- If not, go to step 3.
- Check whether the fan is installed securely.
- If so, collect alarm information and configuration information, and then contact technical support personnel.
- If not, install the fan securely and go to step 4.
- Check whether there is an alarm indicating that a fan is installed.
- If so, the alarm handling ends.
- If not, collect alarm information and configuration information, and then contact technical support personnel.