Configuring Alarm Rules
Scenarios
Setting alarm rules allows you to customize objects to be monitored and notification policies so that you can closely monitor your instances.
Alarm rules include the alarm rule name, instance, metric, threshold, monitoring interval and whether to send notifications. This section describes how to set alarm rules.
For more information about alarm rules, see Cloud Eye User Guide.
Procedure
- Log in to the management console.
- Click Service List. Under Management & Governance, click Cloud Eye.
- In the navigation pane on the left, choose Alarm Management > Alarm Rules.
- On the Alarm Rules page, click Create Alarm Rule.
Figure 1 Creating an alarm rule
- Set alarm parameters.
- Configure basic alarm information.
Figure 2 Configuring basic information for an alarm rule
Table 1 Basic alarm rule information Parameter
Description
Example Value
Name
Name of the rule. The system generates a random name and you can modify it.
alarm-cag2
Description
(Optional) Alarm rule description.
-
- Select objects to be monitored and specify the monitoring scope.
Table 2 Parameter description Parameter
Description
Example Value
Alarm Type
Alarm type that the alarm rule is created for. The value can be Metric or Event.
Metric
Resource Type
Type of the resource the alarm rule is created for.
Select GeminiDB.
-
Dimension
Metric dimension of the alarm rule.
Select InfluxDB-InfluxDB Nodes.
-
Monitoring Scope
Monitoring scope the alarm rule applies to.
NOTE:- If you select All resources, an alarm notification will be sent when any instance meets an alarm policy, and existing alarm rules will be automatically applied for newly purchased resources.
- If you select Resource groups and any resource in the group meets the alarm policy, an alarm notification will be sent.
- To specify Specific resources, click Select Specified Resources, select one or more resources, and click OK.
All Resources
Group
This parameter is mandatory when Monitoring Scope is set to Resource groups.
-
- Configure an alarm policy.
Table 3 Parameter description Parameter
Description
Example Value
Method
Select Associate template, Use existing template, or Configure manually.
NOTE:If you set Monitoring Scope to Specific resources, you can set Method to Use existing template.
Configure manually
Template
Select the template to be used.
This parameter is available only when you select Use existing template for Method.
-
Alarm Policy
Policy for triggering an alarm. You can configure the threshold, consecutive periods, alarm interval, and alarm severity based on service requirements.
- Metric Name: specifies the metric that the alarm rule is created for.
The following metrics are recommended:
Storage Space Usage,
which is used to monitor the storage usage of GeminiDB Influx instances. If the storage usage is greater than 80%, scale up the storage in a timely manner by referring to Scaling Up Storage Space.
CPU Usage and Memory Usage,
which are used to monitor the compute resource usage of each GeminiDB Influx instance node. If the CPU usage or memory usage is greater than 80%, you can add nodes or upgrade node specifications in a timely manner.
For more metrics, see GeminiDB Influx Metrics.
- Alarm Severity: specifies the severity of the alarm. Valid values are Critical, Major, Minor, and Informational.
NOTE:
A maximum of 50 alarm policies can be added to an alarm rule. If any one of these alarm policies is met, an alarm is triggered.
Take the CPU usage as an example. The alarm policy configured in Figure 3 indicates that a major alarm notification will be sent to users every 10 minutes if the original CPU usage reaches 80% or above for three consecutive periods.
- Metric Name: specifies the metric that the alarm rule is created for.
- Configure alarm notification information.
Figure 4 Configuring alarm notification information
Table 4 Parameter description Parameter
Description
Example Value
Alarm Notification
Whether to notify users when alarms are triggered. Notifications can be sent by email, text message, or HTTP/HTTPS message.
Enabling alarm notification is recommended. When the metric data reaches the threshold set in the alarm rule, Cloud Eye immediately notifies you through SMN that an exception has occurred.
Enabled Alarm Notification.
Notification Recipient
Select Notification group or Topic subscription.
-
Notification Group
Notification group the alarm notification is to be sent to.
-
Notification Object
Specifies the object that receives alarm notifications. You can select the account contact or a topic.
- Account contact is the mobile phone number and email address provided for registration.
- Topic is used to publish messages and subscribe to notifications. If the required topic is unavailable, create one first and add subscriptions to it.
For details, see Creating a Topic and Adding Subscriptions.
-
Notification Window
Cloud Eye sends notifications only within the notification window specified in the alarm rule.
For example, if Notification Window is set to 00:00-8:00, Cloud Eye sends notifications only within 00:00-08:00.
-
Trigger Condition
Condition for triggering an alarm notification. You can select Generated alarm (when an alarm is generated), Cleared alarm (when an alarm is cleared), or both.
-
- Configure advanced settings.
Figure 5 Advanced settings
Table 5 Parameter description Parameter
Description
Example Value
Enterprise Project
Enterprise project that the alarm rule belongs to. Only users with the enterprise project permissions can view and manage the alarm rule. For details about how to create an enterprise project, see Creating an Enterprise Project.
default
Tag
A tag is a key-value pair. Tags identify cloud resources so that you can easily categorize and search for your resources. You are advised to create predefined tags on TMS. For details about how to create predefined tags, see Creating Predefined Tags.
- A key can contain a maximum of 128 characters, and a value can contain a maximum of 225 characters.
- A maximum of 20 tags can be added.
-
- Configure basic alarm information.
- After the configuration is complete, click Create.
When the metric data reaches the threshold set in the alarm rule, Cloud Eye immediately notifies you through SMN that an exception has occurred.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot