Connecting an MRS Cluster to the Syslog Server to Report Alarms
If users need to view alarms and events of a cluster on the unified alarm reporting platform, you can use the Syslog protocol on FusionInsight Manager to report related data to the alarm platform.
If the Syslog protocol is not encrypted, data may be stolen.
Prerequisites
The ECS corresponding to the server must be in the same VPC as the MRS cluster's Master node, and the Master node must be able to access the server's IP address and specified port.
Connecting an MRS Cluster to the Syslog Server to Report Alarms
- Log in to the Manager and go to the SNMP configuration page.
- MRS 3.x or later:
- Log in to FusionInsight Manager.
- Choose System > Interconnection > Syslog.
- Enable the Syslog service.
- Versions earlier than MRS 3.x:
- Log in to MRS Manager and click System.
- In Configuration, enable Configure Syslog under Monitoring and Alarm.
- MRS 3.x or later:
- Set northbound parameters based on Table 1.
Table 1 Syslog interconnection parameters Parameter Area
Parameter
Description
Syslog Protocol
Server IP Address Mode
Specifies the IP address mode of the interconnected server. The value can be IPV4 or IPV6. (only for MRS 3.x or later)
Server IP Address
Specifies the IP address of the interconnected server.
Server Port
Specifies the port number for interconnection.
Protocol
Specifies the protocol type. The options are as follows:
- TCP
- UDP
Severity Level
Specifies the severity of the reported message. The options are as follows:
- Emergency
- Alert
- Critical
- Error
- Warning
- Notice
- Informational (default value)
- Debug
NOTE:
Severity Level and Facility determine the priority of the sent message.
Priority = Facility × 8 + Severity Level
For the values of Severity Level and Facility, see Table 2.
Facility
Specifies the module where the log is generated. For the available values of this parameter, see Table 2. Default value local use 0 (local0) is recommended.
Identifier
Product ID.
The identifier can contain a maximum of 256 characters, including letters, digits, underscores (_), periods (.), hyphens (-), spaces, and the following special characters: | $ { }
- MRS 3.x or later: The default value is FusionInsight Manager.
- Versions earlier than MRS 3.x: The default value is MRS Manager.
Report Message
Report Format
Specifies the message format of the alarm report. For details, see the help information on the page.
The report format can contain a maximum of 1024 characters, including letters, digits, underscores (_), periods (.), hyphens (-), spaces, and the following special characters: | $ { }
NOTE:For details about each field in the report format, see Table 3.
Alarm Type
Specifies the type of the alarm to be reported.
- For MRS 3.x or later, see Table 3.
- Versions earlier than MRS 3.x:
- Fault: indicates that the Syslog alarm message is reported when MRS Manager generates an alarm.
- Clear: indicates that a Syslog alarm message is reported when an alarm on MRS Manager is cleared.
- Event: indicates that the Syslog alarm message is reported when MRS Manager generates an event.
Alarm Severities
Specifies the level of the alarm to be reported.
- For MRS 3.x or later, see Table 3.
- Versions earlier than MRS 3.x: Suggestion, Minor, Major, and Critical.
Uncleared Alarm Reporting
Periodic Uncleared Alarm Reporting
Specifies whether to report uncleared alarms in a specified period. You can toggle on or off the function. The function is toggled off by default.
Report Interval (min)
Specifies the interval for periodically reporting uncleared alarms. This parameter is valid only when Periodic Uncleared Alarm Reporting is enabled. The default value is 15, in minutes. The value ranges from 5 to 1440 (one day).
Heartbeat Settings
Heartbeat Reporting
Specifies whether to periodically report Syslog heartbeat messages. You can toggle on or off the function. The function is toggled off by default.
Heartbeat Interval (minutes)
Specifies the interval for periodically reporting heartbeat messages. This parameter is valid only when Heartbeat Reporting is enabled. The default value is 15, in minutes. The value ranges from 1 to 60.
Heartbeat Packet
Specifies the heartbeat message to be reported. This parameter is valid when Heartbeat Reporting is toggled on and cannot be left blank. The value can contain a maximum of 256 characters, including digits, letters, underscores (_), vertical bars (|), colons (:), spaces, commas (,), and periods (.).
After the periodic heartbeat packet function is enabled, packets may be interrupted during automatic recovery of some cluster error tolerance (for example, active/standby OMS switchover). In this case, wait for automatic recovery.
- Click OK.
Related Information
Severity Level |
Facility |
Numeric Code |
---|---|---|
Emergency |
kernel messages |
0 |
Alert |
user-level messages |
1 |
Critical |
mail system |
2 |
Error |
system daemons |
3 |
Warning |
security/authorization messages (note 1) |
4 |
Notice |
messages generated internally by syslog |
5 |
Informational |
line printer subsystem |
6 |
Debug |
network news subsystem |
7 |
- |
UUCP subsystem |
8 |
- |
clock daemon (note 2) |
9 |
- |
security/authorization messages (note 1) |
10 |
- |
FTP daemon |
11 |
- |
NTP subsystem |
12 |
- |
log audit (note 1) |
13 |
- |
log alert (note 1) |
14 |
- |
clock daemon (note 2) |
15 |
- |
local use 0~7 (local0 ~ local7) |
16 to 23 |
Information Field |
Description |
---|---|
dn |
Cluster name |
id |
Alarm ID |
name |
Alam name |
serialNo |
Alarm serial number
NOTE:
The serial numbers of the fault alarms and the corresponding clear alarms are the same. |
category |
Alarm type. The options are as follows:
|
occurTime |
Time when the alarm was generated |
clearTime |
Time when this alarm was cleared |
isAutoClear |
Whether an alarm is automatically cleared. The options are as follows:
|
locationInfo |
Location where the alarm was generated |
clearType |
Alarm clearance type. The options are as follows:
|
level |
Severity. The options are as follows:
|
cause |
Alarm cause |
additionalInfo |
Additional information |
object |
Alarm object |
Feedback