Help Center/ MapReduce Service/ User Guide/ MRS Cluster O&M/ MRS Cluster Alarm Handling Reference/ ALM-50808 Number of StoreMaster Failures to Create Spaces Exceeds the Threshold
Updated on 2026-09-24 GMT+08:00

ALM-50808 Number of StoreMaster Failures to Create Spaces Exceeds the Threshold

Alarm Description

The system checks whether StoreMaster fails to create a space every 30 seconds. This alarm is generated when StoreMaster fails to create a space.

This alarm is cleared when no space fails to be created.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

50808

Critical

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster or system for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

RoleName

Specifies the role for which the alarm was generated.

HostName

Specifies the host for which the alarm was generated.

Impact on the System

The corresponding Spark task fails.

Possible Causes

Access to ZooKeeper is abnormal.

Handling Procedure

Check the ZooKeeper instance status.

  1. On FusionInsight Manager, choose Cluster > Services > ZooKeeper > Instances.
  2. Check whether ZooKeeper instances are normal.

  3. Select the instances whose status is not Normal, click More, and select Restart Instance.
  4. Check whether the instance status becomes normal after the restart.

  5. Choose O&M > Alarm > Alarms and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select MemArtsStore for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M engineers and send the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None