ALM-47003 Memory Usage of the MemArtsCC Worker Process Exceeds the Threshold
This section is available for MRS 3.5.0 or later version only.
Alarm Description
The system checks the memory usage of the CCWorker process of the MemArtsCC component every 30 seconds. This alarm is generated when the memory usage exceeds the threshold.
This alarm is cleared when the system detects that the memory usage of CCWorker process is lower than the threshold.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
47003 |
Major |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
|
RoleName |
Specifies the role for which the alarm is generated. |
|
HostName |
Specifies the host for which the alarm is generated. |
Impact on the System
The CCWorker process process may restart, which temporarily reduces the cache hit ratio.
Possible Causes
There is more disk space added to CCWorker, there is a sudden increase in service data, or the workload increases significantly when upper-layer computing services (such as Spark, Hive, and HetuEngine) sent many concurrent requests to the MemArtsCC component.
Handling Procedure
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, search for ALM-47003 Memory Usage of the MemArtsCC Worker Process Exceeds the Threshold, and locate the abnormal MemArtsCC instance node based on the alarm information. Obtain the alarm threshold in additional information.
- Choose Cluster > Services > MemArtsCC > Configurations > All Configurations > CCWorker (Role), search for the memory_limit parameter, and check the maximum available memory of the CCWorker instance in the current cluster. Check whether the service concurrency and data volume increase for a long time and the alarm is not automatically cleared.
- This alarm can be ignored temporarily. After the service peak hours, the alarm will be automatically cleared.
- Increase the maximum available memory in 2 and click Save.
- Choose O&M > Alarm > Alarms and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 6.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select MemArtsCC for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and send the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.