ALM-45451 ClickHouse Failed to Access OBS
This section is available for MRS 3.3.1 or later version only.
Alarm Description
When cold-hot separation is enabled, the system checks the OBS access every minute. This alarm is generated when the system detects that OBS cannot be accessed for three consecutive times.
This alarm is automatically cleared when the system successfully accesses OBS.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45451 |
Critical |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster or system for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
Impact on the System
For tables configured with the cold-hot separation policy, cold data on OBS cannot be read or written. Hot data on local disks cannot be moved to OBS.
Possible Causes
- Parameters such as the endpoint used by ClickHouse to access OBS are incorrect.
- OBS is abnormal.
Handling Procedure
- Check whether the cold and hot separation configuration is correct. If the configuration is incorrect, modify the configuration and restart the ClickHouse instance. Wait for 3 minutes and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 2.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select ClickHouse for the target cluster.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M engineers and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.