Full or Incremental Phase Error: Can not read response from server
Scenarios
During a full or incremental migration or synchronization, an error is reported, and the log information is as follows: service LOGMANAGER failed, cause by: Can not read response from server. Expected to read 4 bytes, read 0 bytes before connection was unexpectedly lost.
Possible Causes
- The network bandwidth between the DRS replication instance and the source database is too small or unstable.
- The source database is overloaded.
Solution
Contact the source database O&M personnel to check the source database load and check whether packet loss occurs on the network between the source database and the replication instance.