Halaman ini belum tersedia dalam bahasa lokal Anda. Kami berusaha keras untuk menambahkan lebih banyak versi bahasa. Terima kasih atas dukungan Anda.

Compute
Elastic Cloud Server
Huawei Cloud Flexus
Bare Metal Server
Auto Scaling
Image Management Service
Dedicated Host
FunctionGraph
Cloud Phone Host
Huawei Cloud EulerOS
Networking
Virtual Private Cloud
Elastic IP
Elastic Load Balance
NAT Gateway
Direct Connect
Virtual Private Network
VPC Endpoint
Cloud Connect
Enterprise Router
Enterprise Switch
Global Accelerator
Management & Governance
Cloud Eye
Identity and Access Management
Cloud Trace Service
Resource Formation Service
Tag Management Service
Log Tank Service
Config
OneAccess
Resource Access Manager
Simple Message Notification
Application Performance Management
Application Operations Management
Organizations
Optimization Advisor
IAM Identity Center
Cloud Operations Center
Resource Governance Center
Migration
Server Migration Service
Object Storage Migration Service
Cloud Data Migration
Migration Center
Cloud Ecosystem
KooGallery
Partner Center
User Support
My Account
Billing Center
Cost Center
Resource Center
Enterprise Management
Service Tickets
HUAWEI CLOUD (International) FAQs
ICP Filing
Support Plans
My Credentials
Customer Operation Capabilities
Partner Support Plans
Professional Services
Analytics
MapReduce Service
Data Lake Insight
CloudTable Service
Cloud Search Service
Data Lake Visualization
Data Ingestion Service
GaussDB(DWS)
DataArts Studio
Data Lake Factory
DataArts Lake Formation
IoT
IoT Device Access
Others
Product Pricing Details
System Permissions
Console Quick Start
Common FAQs
Instructions for Associating with a HUAWEI CLOUD Partner
Message Center
Security & Compliance
Security Technologies and Applications
Web Application Firewall
Host Security Service
Cloud Firewall
SecMaster
Anti-DDoS Service
Data Encryption Workshop
Database Security Service
Cloud Bastion Host
Data Security Center
Cloud Certificate Manager
Edge Security
Managed Threat Detection
Blockchain
Blockchain Service
Web3 Node Engine Service
Media Services
Media Processing Center
Video On Demand
Live
SparkRTC
MetaStudio
Storage
Object Storage Service
Elastic Volume Service
Cloud Backup and Recovery
Storage Disaster Recovery Service
Scalable File Service Turbo
Scalable File Service
Volume Backup Service
Cloud Server Backup Service
Data Express Service
Dedicated Distributed Storage Service
Containers
Cloud Container Engine
SoftWare Repository for Container
Application Service Mesh
Ubiquitous Cloud Native Service
Cloud Container Instance
Databases
Relational Database Service
Document Database Service
Data Admin Service
Data Replication Service
GeminiDB
GaussDB
Distributed Database Middleware
Database and Application Migration UGO
TaurusDB
Middleware
Distributed Cache Service
API Gateway
Distributed Message Service for Kafka
Distributed Message Service for RabbitMQ
Distributed Message Service for RocketMQ
Cloud Service Engine
Multi-Site High Availability Service
EventGrid
Dedicated Cloud
Dedicated Computing Cluster
Business Applications
Workspace
ROMA Connect
Message & SMS
Domain Name Service
Edge Data Center Management
Meeting
AI
Face Recognition Service
Graph Engine Service
Content Moderation
Image Recognition
Optical Character Recognition
ModelArts
ImageSearch
Conversational Bot Service
Speech Interaction Service
Huawei HiLens
Video Intelligent Analysis Service
Developer Tools
SDK Developer Guide
API Request Signing Guide
Terraform
Koo Command Line Interface
Content Delivery & Edge Computing
Content Delivery Network
Intelligent EdgeFabric
CloudPond
Intelligent EdgeCloud
Solutions
SAP Cloud
High Performance Computing
Developer Services
ServiceStage
CodeArts
CodeArts PerfTest
CodeArts Req
CodeArts Pipeline
CodeArts Build
CodeArts Deploy
CodeArts Artifact
CodeArts TestPlan
CodeArts Check
CodeArts Repo
Cloud Application Engine
MacroVerse aPaaS
KooMessage
KooPhone
KooDrive
Help Center/ Enterprise Switch/ User Guide (Ankara Region)/ Getting Started/ Step 4: Configure a Tunnel Gateway in Your Data Center

Step 4: Configure a Tunnel Gateway in Your Data Center

Updated on 2024-12-04 GMT+08:00

Scenarios

This section describes how to configure the tunnel gateway on a VXLAN tunnel switch of an on-premises data center.

The following uses CE6850 and H3C S6520 series switches as examples. To check more configurations, see the product documentation of the corresponding switch.

Notes and Constraints

If you use an enterprise switch to connect your on-premises data center to the cloud, the switches of your data center must support the VXLAN function. If high reliability is required, the VXLAN switches need to be deployed in disaster recovery mode.

The following lists some switches that support the VXLAN function.
  • Huawei switches: Huawei CE58, CE68, CE78, and CE88 series switches, such as CE6870, CE6875, CE6881, CE6863, and CE12800 switches
  • Switches of other vendors: Cisco Nexus 9300 and H3C S6520 series switches

Networking Example

In this example, the Layer 2 subnet gateway and the VXLAN tunnel are on different switches.

The tunnel IP address on the cloud is 10.0.6.3, the tunnel IP address of the tunnel switch on the on-premises data center is 2.2.2.2, and the tunnel VNI is 5010.

Figure 1 Layer 2 subnet gateway and VXLAN tunnel on different switches

Procedure (CE6850 Switches)

Configure the tunnel switch of your data center to divert the traffic of the VLAN corresponding to the Layer 2 subnet to the tunnel.

NOTICE:

Currently, most CE series switches do not support forwarding of encapsulated VXLAN packets through Layer 3 sub-interfaces. Layer 3 sub-interfaces cannot be used by VXLAN uplinks (connected to enterprise switches). Instead, VLAN interfaces can be used.

  1. Log in to the tunnel switch and run the system-view command to switch to the system view.
  2. Switch to the loopback 0 interface view and configure the tunnel IP address.

    Example:

    interface loopback 0

    ip address 2.2.2.2 255.255.255.255

  1. Use the quit command to exit the interface view and return to the system view.
  2. Switch to the bridge domain (BD) view and configure the VXLAN VNI for the BD.

    Example:

    bridge-domain 10

    vxlan vni 5010

  3. Use the quit command to exit the BD view and return to the system view.
  4. Create a Layer 2 sub-interface and use the sub-interface to divert traffic from the VLAN at Layer 2 to the tunnel.

    Example:

    interface 10ge 1/0/2.1 mode l2

    encapsulation dot1q vid 100

    bridge-domain 10

  1. Use the interface nve command to create an NVE interface, switch to the NVE interface view, and configure the IP address (2.2.2.2) for the source VTEP of the VXLAN tunnel.

    Example:

    interface nve1

    source 2.2.2.2

  1. Use the vni command in the NVE interface view to configure an ingress replication list for VNI 5010.

    Example:

    vni 5010 head-end peer-list 10.0.6.3

  2. Check the VXLAN configuration status in the system view:

    display vxlan vni 5010 verbose

    Figure 2 VXLAN configuration status

    If the value of State is up, the tunnel status is normal.

Procedure (H3C S6520 Switches)

Establish a VXLAN tunnel between a VXLAN switch and an enterprise switch, associate the VXLAN tunnel with a VXLAN, so that Layer 2 packets from VMs can be encapsulated into IP packets and then sent to the enterprise switch. Configure Ethernet service instances and matching rules on downlink interfaces of a VXLAN switch to identify the VXLAN that packets belong to.

  1. Configure the switch to work in VXLAN mode.

    Save the configuration, and restart the switch. (Skip this step if the switch is already working in VXLAN mode.)

    Example:

    <SwitchA> system-view

    [SwitchA] switch-mode 1

    Reboot device to make the configuration take effect.

    [SwitchA] quit

    <SwitchA> reboot

    Start to check configuration with next startup configuration file, please wait..
    .......DONE!
    Current configuration may be lost after the reboot, save current configuration?
    [Y/N]:y
    This command will reboot the device. Continue? [Y/N]:y
  1. Create a tunnel interface and configure an IP address for the interface.

    Create a loopback interface and configure an IP address for the loopback interface as the remote IP address of the VXLAN tunnel.

    Example:

    [SwitchA] interface loopback 0

    [SwitchA-LoopBack0] ip address 2.2.2.2 32

    NOTICE:

    For a new interface IP address (including the loopback interface IP address) of the VXLAN switch, check whether there is a route to direct traffic from the IP address to the tunnel subnet of the enterprise switch. If there is no such a route, configure one on the VXLAN switch. The VXLAN switch can be an aggregation switch or a core switch. Select a switch based on the network plan.

  2. Create a VXLAN.
    1. Enable L2VPN.

      Example:

      <SwitchA> system-view

      [SwitchA] l2vpn enable

    2. Enable Layer 2 forwarding for the VXLAN tunnel.

      Example:

      [SwitchA] undo vxlan ip-forwarding

    3. Create the VSI vpna and VXLAN 5010.

      Example:

      [SwitchA] vsi vpna

      [SwitchA-vsi-vpna] vxlan 5010

      [SwitchA-vsi-vpna-vxlan5010] quit

      [SwitchA-vsi-vpna] quit

      NOTICE:

      The VXLAN ID must be the same as the tunnel VNI in remote access information configured during Layer 2 connection creation in Table 1.

  3. Create a VXLAN tunnel.

    Create a VXLAN tunnel (Tunnel1) to the enterprise switch.

    Example:

    [SwitchA] interface tunnel 1 mode vxlan

    [SwitchA-Tunnel1] source 2.2.2.2

    [SwitchA-Tunnel1] destination 10.0.6.3

    [SwitchA-Tunnel1] quit

  1. Associate the VXLAN with the VXLAN tunnel.

    On the VXLAN switch, associate the VXLAN tunnel (Tunnel1) with VXLAN 5010.

    Example:

    [SwitchA] vsi vpna

    [SwitchA-vsi-vpna] vxlan 5010

    [SwitchA-vsi-vpna-vxlan5010] tunnel 1

    [SwitchA-vsi-vpna-vxlan5010] quit

    [SwitchA-vsi-vpna] quit

    NOTICE:
    • A maximum of six Layer 2 connections can be created on an enterprise switch. Each connection corresponds to a VXLAN. Multiple VXLANs can be associated with the same VXLAN tunnel, such as, Tunnel1.
    • A VXLAN switch can connect to multiple enterprise switches. In this case, you can associate multiple VXLAN tunnels, for example, Tunnel1 and Tunnel2, with the same VXLAN.
  1. Configure an Ethernet service instance to match frames and associate the instance with the VSI.

    Create Ethernet service instance 1000 on Bridge-Aggregation1 of the VXLAN switch to match frames of VLAN 100 and associate the instance with VSI vpna (VXLAN 5010).

    Example:

    [SwitchA] Bridge-Aggregation 1

    [SwitchA-Bridge-Aggregation1] port link-type trunk

    [SwitchA-Bridge-Aggregation1] service-instance 1000

    [SwitchA-Bridge-Aggregation1-srv1000] encapsulation s-vid 100

    [SwitchA-Bridge-Aggregation1-srv1000] xconnect vsi vpna

    [SwitchA-Bridge-Aggregation1-srv1000] quit

    [SwitchA-Bridge-Aggregation1] quit

    NOTICE:

    The method for creating Ethernet service instances on physical Ethernet interfaces of switches is similar.

  2. Check the status of the VXLAN tunnel interface.
    • The status of the VXLAN tunnel interface is Up.

      Example:

      [SwitchA]display interface Tunnel 1

      Tunnel1
      Current state: UP
      Line protocol state: UP
      Description: Tunnel1 Interface
      Bandwidth: 64 kbps
      Maximum transmission unit: 1464
      Internet protocol processing: Disabled
      Last clearing of counters: 17:19:44 Fri 01/18/2013
      Tunnel source 2.2.2.2, destination 10.0.6.3
      Tunnel protocol/transport UDP_VXLAN/IP
      Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
      Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
      Input: 0 packets, 0 bytes, 4 drops
      Output: 0 packets, 0 bytes, 0 drops
    • Check the VSI information. The VXLAN tunnel associated with the VXLAN and the Ethernet service instance associated with the VSI are in Up status.

      Example:

      [SwitchA]display l2vpn vsi verbose

      VSI Name: vnpa
      VSI Index               : 1
      VSI State               : Up
      MTU                     : 1500
      Bandwidth               : -
      Broadcast Restrain      : -
      Multicast Restrain      : -
      Unknown Unicast Restrain: -
      MAC Learning            : Enabled
      MAC Table Limit         : -
      MAC Learning rate       : -
      Drop Unknown            : -
      Flooding                : Enabled
      Statistics              : Disabled
      VXLAN ID                : 5010
      Tunnels:
      Tunnel Name          Link ID    State    Type        Flood proxy
      Tunnel1              0x5000001  UP       Manual      Disabled
      ACs:
      AC                   Link ID    State    Type
      BAGG1 srv1000        0          Up       Manual