ALM-3276800032 Indicates that card invalid

Description

ENTITYTRAP/1/CARDINVALID: OID [OID] Card is invalid for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The subcard does not work.

Attribute

Alarm ID

Alarm Severity

Alarm Type

3276800032

Critical

environmentalAlarm

Parameters

Name

Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Indicates the alarm ID.

EntityPhysicalIndex

Indicates the index.

PhysicalName

Indicates the physical entity name.

EntityTrapEntType

Indicates the alarm type.

EntityTrapFaultID

Indicates the error code.

EntityTrapReasonDescr

Indicates the description of the alarm cause.

Impact on the System

See the description in the procedure.

Possible Causes

See the description in the procedure.

Procedure

Rectify the fault based on the error code.

Error Code

Possible Causes

Procedure

135435

The subcard does not match the slot where the subcard was installed.

  • The subcard was installed in an unsupported slot.
  • An unsupported subcard was installed in the slot.

Install a subcard matching the slot. For the subcards supported in different subcard slots, see Hardware Description > Chassis > Appearance and Structure.

135475

The subcard is not installed securely or the subcard is faulty and cannot be registered.

  1. Remove the subcard to check whether it has bent pins.
    • If so, repair or replace the subcard.
    • If not, go to step 2.
  2. Reinstall the subcard securely at a time. If it is not installed securely at a time, remove it and then install it securely again.
  3. Check whether the device receives an alarm indicating that the fault has been rectified.
    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.

143620

The power module that provides power for the subcard PHY chip was working abnormally.

  1. Remove and install the subcard to check whether the resume alarm is displayed.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  2. Replace this faulty subcard.

143621

The subcard failed to be powered on because it was not properly installed or a hardware fault occurred.

  1. Remove and install the subcard to check whether the resume alarm is displayed.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  2. Replace this faulty subcard.

143622

The subcard PHY chip or LSW became faulty.

  1. Remove and install the subcard to check whether the resume alarm is displayed.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  2. Replace this faulty subcard.