Modifying Device Information
Typical Scenario
After an NA registers a device with the IoT platform and the basic information about the device changes, the NA can also call this API to modify device information on the IoT platform.
API Function
This API is used to modify the basic information about a device, including the device type, device model, manufacturer, and access protocol.
API Description
1 |
public function modifyDeviceInfo($mdiInDto, $deviceId, $appId, $accessToken)
|
Class
DeviceManagement
Parameter Description
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
$mdiInDto |
Mandatory |
body |
For details, see ModifyDeviceInforInDTO structure. |
$deviceId |
Mandatory |
path |
Identifies a device. The device ID is allocated by the IoT platform during device registration. |
$appId |
Mandatory |
query |
If the device belongs to the current application, set this parameter to null. Otherwise, set this parameter to the ID of the authorized application. |
$accessToken |
Mandatory |
header |
This parameter is set to the value of the access token obtained by calling the Authentication API. |
ModifyDeviceInforInDTO structure
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
$customFields |
Optional |
body |
User-defined field list. Users can set customized fields. For details, see CustomField structure. |
$deviceConfig |
Optional |
body |
Indicates device configuration information. For details, see DeviceConfigDTO structure. |
$deviceType |
Optional |
body |
Indicates the device type. The upper camel case is used, for example, MultiSensor, ContactSensor, and CameraGateway. In the NB-IoT solution, the device type must be changed to be the same as that defined in the profile after a device is registered. |
$endUser |
Optional |
body |
Indicates an end user. If the device is a directly connected device, this parameter is optional. If it is a non-directly connected device, this parameter can be set to null. |
$location |
Optional |
body |
Indicates the device location. |
$manufacturerId |
Optional |
body |
Uniquely identifies a manufacturer. In the NB-IoT solution, the manufacturer ID must be changed to be the same as that defined in the profile after a device is registered. |
$manufacturerName |
Optional |
body |
Indicates the manufacturer name. |
$model |
Optional |
body |
Indicates the device model. In the NB-IoT solution, the model must be changed to be the same as that defined in the profile after a device is registered. |
$mute |
Optional |
body |
Indicates whether the device is in the frozen state. Based on the value of this parameter, the IoT platform determines whether to manage and store data reported by the device.
|
$name |
Optional |
body |
Indicates the device name. |
$organization |
Optional |
body |
Indicates the organization to which the device belongs. |
$protocolType |
Optional |
body |
Indicates the protocol type used by the device. The value options are CoAP, huaweiM2M, Z-Wave, ONVIF, WPS, Hue, WiFi, J808, Gateway, ZigBee, and LWM2M. |
$region |
Optional |
body |
Indicates the region information about a device. |
$timezone |
Optional |
body |
Indicates the time zone where the device is located. The time zone code is used. For example, the time zone code of Beijing time zone is Asia/Beijing. |
$imsi |
Optional |
body |
Indicates the IMSI of an NB-IoT device. |
$ip |
Optional |
body |
Indicates the device IP address. |
$isSecure |
Optional |
body |
Indicates the security status of a specified device. The default value is false.
|
$psk |
Optional |
body |
Indicates the PSK. The value is a string of characters that consist of only upper-case letters A to F, lower-case letters a to f, and digits 0 to 9. |
$tags |
Optional |
body |
Indicates the device tag information. For details, see Tag2 structure. |
Parameter |
Mandatory or Optional |
Location |
Description |
---|---|---|---|
fieldName |
Optional |
Body |
Indicates the field name. |
fieldType |
Optional |
Body |
Indicates the field type. |
fieldValue |
Optional |
Body |
Indicates the field value. |
Parameter |
Mandatory or Optional |
Description |
---|---|---|
$dataConfig |
Optional |
Indicates data configuration information. For details, see DataConfigDTO structure. |
Parameter |
Mandatory or Optional |
Type |
Description |
---|---|---|---|
$dataAgingTime |
Optional |
Integer |
Indicates the data aging time. The value range is 0-90. Unit: day. |
Parameter |
Mandatory or Optional |
Type |
Location |
Description |
---|---|---|---|---|
tagName |
Mandatory |
String(1-128) |
body |
Indicates the tag name. |
tagValue |
Mandatory |
String(1-1024) |
body |
Indicates the tag value. |
tagType |
Optional |
Integer |
body |
Indicates the tag type. |
Return Value
response: Status Code: 200 OK
Error Codes
HTTP Status Code |
Error Code |
Error Description |
Remarks |
---|---|---|---|
200 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
400 |
100022 |
The input is invalid. |
An input parameter is invalid. Recommended handling: Check whether parameters carried in the API call request are valid. |
400 |
100440 |
The isSecure is invalid. |
The value of isSecure is incorrect. |
400 |
50400 |
The input is invalid. |
An input parameter is invalid. Recommended handling: Check whether parameters carried in the API call request are valid. |
403 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
403 |
100217 |
The application hasn't been authorized. |
The application has not been authorized. Recommended handling: In scenarios where applications are not authorized, ensure that request parameter appId is null. |
403 |
1010009 |
app throttle exceed. |
The NA calls the API at a frequency that exceeds the flow control threshold (100 calls per minute by default). Recommended handling: Contact IoT platform maintenance personnel to adjust the flow control threshold or control the API call frequency. |
403 |
1010005 |
App_key or access_token is invalid. |
The access token is invalid. Recommended handling: Check whether accessToken carried in the API request is correct. |
403 |
500004 |
The amount of frozen devices has reached the limit. |
The number of frozen devices has reached the upper limit. |
404 |
100403 |
The device is not existed. |
The device does not exist. Recommended handling: Check whether deviceId is correct. |
404 |
100418 |
The deviceData is not existed. |
The device data does not exist. Recommended handling:
|
500 |
100203 |
The application is not existed. |
The application does not exist. Recommended handling:
|
500 |
100441 |
The amount of nonSecure device has reached the limit. |
The number of non-security devices has reached the upper limit. |
500 |
50252 |
Internal server error. |
An internal server error occurs. Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel. |
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot