Creating an Alarm Rule
This topic describes how to create an alarm rule.
Creating an Alarm Rule
- Log in to the management console.
- Click Service List in the upper left corner and select Cloud Eye.
- In the navigation pane on the left, choose Alarm Management > Alarm Rules.
- Click Create Alarm Rule in the upper right corner.
- On the Create Alarm Rule page, configure the parameters.
- Configure the alarm rule name and description.
- Select a monitored object and configure alarm content parameters.
Table 2 Parameters Parameter
Description
Example Value
Resource Type
Specifies the type of the resource the alarm rule is created for.
Elastic Cloud Server
Dimension
Specifies the metric dimension of the selected resource type.
ECSs
Monitoring Scope
The monitoring scope of an alarm rule can be All resources, Resource groups, or Specified resources.
NOTE:- If you select All resources, an alarm notification will be sent when any instance meets an alarm policy, and existing alarm rules will be automatically applied for newly purchased resources.
- If Resource groups is selected and any resource in the group meets the alarm policy, an alarm is triggered.
- If you select Specific resources, select one or more resources and click to add them to the box on the right.
All resources
Group
This parameter is mandatory when Monitoring Scope is set to Resource groups.
N/A
Method
You can select an associated template, use an existing template or create a custom template as required.
NOTE:After an associated template is modified, the policies contained in this alarm rule to be created will be modified accordingly.
Configure manually
Template
Specifies the template to be used.
You can select a default alarm template or customize a template.
ECS Alarm Template
Alarm Policy
Specifies the policy for triggering an alarm.
If you set Resource Type to Custom Monitoring or a specific cloud service, whether an alarm will be triggered depends on whether the metric data in consecutive periods reaches the threshold. For example, Cloud Eye triggers an alarm if the average CPU usage of the monitored object is 80% or more for three consecutive 5-minute periods.
If you set Resource Type is to Event Monitoring, the event that triggers the alarm is an instant event. For example, if event improper ECS running occurs, Cloud Eye triggers an alarm.
NOTE:A maximum of 50 alarm policies can be added to an alarm rule. If any one of these alarm policies is met, an alarm is triggered.
N/A
Mount Point or Disk
This parameter is displayed on the console and can be configured only when the following conditions are met:
- Monitoring Scope: Specific resources
- Resource Type: ECSs or BMSs
- Trigger Rule: Configure manually.
- Metric Name in an alarm policy: disk metric whose name is prefixed with Agent
For the Windows OS, enter a drive letter, such as C, D, or E. For the Linux OS, enter a mount point, such as /dev or /opt.
/dev
Alarm Severity
Specifies the alarm severity, which can be Critical, Major, Minor, or Informational.
Major
- Configure the alarm notification.
Table 3 Alarm Notification parameters Parameter
Description
Alarm Notification
Specifies whether to notify users when alarms are triggered. Notifications can be sent by email, SMS message, or HTTP/HTTPS message.
Notification Object
Specifies the object to which alarm notifications will be sent. You can select the account contact or a topic.
- The account contact is the tenant owner. If a user registers both a mobile number and an email address, they will receive alarm information through both channels. However, if only one of these contact methods is registered, the alarm information will be sent exclusively to that registered one.
- A topic is a specific event type for publishing messages or subscribing to notifications. If the required topic is not available, create one first and add subscriptions to it. For details, Creating a Topic and Adding Subscriptions.
Validity Period
Cloud Eye sends notifications only within the notification window specified in the alarm rule.
If Validity Period is set to 08:00-20:00, Cloud Eye sends notifications only from 08:00 to 20:00.
Trigger Condition
Specifies the condition for triggering an alarm notification.
- If Alarm Type is set to Metric, you can select Generated alarm, Cleared alarm, or both.
- If Alarm Type is set to Event, you can select Generated alarm only.
- Select an enterprise project.
Figure 1 Advanced Settings
Table 4 Name and Description Parameter
Description
Enterprise Project
Specifies the enterprise project that the alarm rule belongs to. Only users with the enterprise project permissions can manage the alarm rule. For details about how to create an enterprise project, see Creating an Enterprise Project.
- Click Create.
After the alarm rule is created, if the metric data reaches the specified threshold or the specified events reach the alarm policies, Cloud Eye immediately informs you that an exception has occurred.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.See the reply and handling status in My Cloud VOC.
For any further questions, feel free to contact us through the chatbot.
Chatbot