ALM-16052 Latency for MetaStore to Access the Meta Database During Table Creation Exceeds the Threshold
Alarm Description
The system periodically checks the latency for MetaStore to access the meta database during table creation. This alarm is generated when the average latency in the last 5 minutes exceeds the threshold.
This alarm is cleared when the average latency falls below the threshold.
This alarm applies to MRS 3.5.0 or later.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
16052 |
Critical (default threshold: 60 seconds) Major (default threshold: 10 seconds) |
Yes |
Alarm Parameters
Type |
Parameter |
Description |
---|---|---|
Location Information |
Source |
Specifies the cluster for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
|
RoleName |
Specifies the role for which the alarm was generated. |
|
HostName |
Specifies the host for which the alarm was generated. |
|
Additional Information |
Trigger Condition |
Specifies the alarm triggering condition. |
Impact on the System
If this alarm is generated, the latency for inserting related table information to the meta database is high during table creation in MetaStore. As a result, calling to MetaStore APIs becomes slow or an error occurs.
Possible Causes
The MetaStore GC takes a long time or the meta database is abnormal (for example, the disk I/O usage is too high or there are too many long transactions).
Handling Procedure
Check whether the GC time of MetaStore is too long.
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and check whether alarm Heap Memory Usage of the Hive Process Exceeds the Threshold exists in the alarm list.
- Rectify the fault by following the handling procedure of ALM-16005 Heap Memory Usage of the Hive Process Exceeds the Threshold.
- Check whether the alarm is cleared in the alarm list.
- If yes, no further action is required.
- If no, go to 4.
Check whether the meta database is normal.
- Contact the administrator of the cluster meta database to check whether the database is normal.
- Contact the meta database O&M engineers to rectify the fault. After the meta database is restored, check whether the alarm is cleared in the alarm list.
- If yes, no further action is required.
- If no, go to 6.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select Hive for the target cluster.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- On FusionInsight Manager, choose Cluster > Services > Hive. On the displayed Dashboard page, click More and select Collect Stack Information. On the displayed page, set the following parameters:
- Select MetaStore for the role where you want to collect data.
- Select jstack and Enable continuous collection of jstack and jmap -histo information.
- Set the collection interval to 10 seconds and the duration to 2 minutes.
- Click OK. After the collection is complete, click Download.
- Contact O&M engineers and provide the collected logs and stack information.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.