Help Center/ ModelArts/ Troubleshooting/ Inference Deployment (New Version)/ Service Prediction/ Error ModelArts.8803 Occurred in Real-Time Service Prediction
Updated on 2026-11-10 GMT+08:00

Error ModelArts.8803 Occurred in Real-Time Service Prediction

Symptom

After a real-time service is deployed and running, an inference request is sent to the service, but error ModelArts.8803 occurred. A common accompanying error message is: Request Failed: EOF.

Possible Causes

The ModelArts.8803 error indicates that the inference forwarding component failed to pass the request to the inference server.

The Request Failed: EOF error is typically triggered when the client request timeout is longer than the inference server connection timeout. If the server times out and closes the connection just as the client attempts to reuse that connection to send a request, the client will receive an EOF while trying to read the response from the server.

Solution

Verify the client request timeout and the inference server connection timeout. You can configure the request timeout settings during service deployment or by modifying the service configuration.

Based on your verification, adjust either the client-side request timeout or the server-side connection timeout to ensure that the client request timeout is shorter than the inference server connection timeout. Best practice: Set the server connection timeout to 1.2 to 1.5 times the client request timeout.

To modify the client request timeout, change the value of Request Timeout in the real-time service configuration.

  1. Log in to the ModelArts console and choose Model Inference > Real-Time Inference.
  2. In the service list, choose More > Modify Service in the Operation column of the target service. In the HA configuration, modify Request Timeout and click Confirm to submit the modification.