Failed to Use Model Warmup for a Real-Time Service
Error "ModelArts.8137" Is Reported During Real-Time Service Deployment
Possible causes:
- The service selects warmed weights. This error is reported during service deployment. The model warmup task may be deleted.
- The service selects warmed weights. This error is reported during service upgrade or scaling. The model warmup task may be deleted.
Solution:
- Warm up the model weights again. After the model is warmed up, select it to deploy or upgrade the service on the inference platform.
- Service modification scenario:
Warm up the model weights again. After the model is warmed up, select it to upgrade the service on the inference platform.
Service scaling scenario:
If the model warmup task is deleted, the number of nodes can only be increased through upgrade. Procedure: Create a model warmup task again. After the model warmup task is successful, modify the service to be scaled, select the warmed model file, and upgrade the service.
Error "ModelArts.8138" Is Reported During Real-Time Service Deployment or Modification
Possible causes:
The service selects warmed model weights. During background verification, the status of the warmup task is not successful.
Solution:
Try again later or check the warmup task.